46
DD1010 FLYNET
5.2.1.1.5 Configurable Sum Scale
In the "Configurable sum scale" version, the sum result is processed as an additional scale with its
own characteristics (capacity, division, zero management, tare management, etc.).
To create a configurable sum scale, press "ADD", select the configurable sum scale and confirm.
Select which scales are used to create the sum scale by double-clicking on them.
The Scale 'S' (sum) is then displayed, select it to view the following data:
CHARACTERISTICS
SPECIFICATIONS
Number of sums per second
(if 0 is the sum at each
second)
Default value 10, indicates how many times the sum is calculated
per second. It is closely related to the reading time of the converter
of the summed scales.
Full scale control on each
scale
If enabled, a full scale control is performed on each scale used to
make the sum scale.
This control is performed to avoid overloading the scales.
Zero enabled on all scales
If enabled, it allows zeroing the scale in addition to the sum scale
itself, the scales used for the sum scale, if and only if, they are
within the reset range.
Minimum weighing
See definition on page 31, chapter 5.2.1.1.
Capacity
See definition on page 31, chapter 5.2.1.1.
Division
See definition on page 31, chapter 5.2.1.1.
Unit of measurement
See definition on page 31, chapter 5.2.1.1.
Legal scale
See definition on page 31, chapter 5.2.1.1.
Regulations
See definition on page 31, chapter 5.2.1.1.