35
DD1010 FLYNET
Divisions
1
may vary while the weight stable signal is maintained. On
indicators subject to metrical verification, this parameter must
be set to 0 (zero) or 1.
2
4
Stability Signal
Very fast (5
e)
Speed at which the stable weight signal is displayed.
Indicates how many equal consecutive readings are
necessary to obtain the stable weight signal. These
consecutive readings may vary according to the number of
divisions indicated in the previous field. This parameter is
also related to the setting of the digital filter parameter.
Fast
(10 e)
Slow
(20 e)
Very slow
(40 e)
Digital Filter
Allows adding or not a digital filter. It actually enables the addition or not of a
software processing for filtering the output values from the analogue/digital
converter. The higher the number, the greater the filtering.
No, 4, 8, 16, 32, 64, 128,
Filter 2hz, Filter 2hz+
average, Filter 5hz+
average, Filter 5hz and
ADVANCED.
Selectable parameters, 4 additional
parameters are available by setting
“ADVANCED”.
ADVANCED
Number of values
per Average
Size of averaged
values table
Number of fields per
average skip
Value to determine
when to delete the
average.
FIR Filter
no, 2Hz/60db,
5Hz/60db, 2Hz/100db
High monotony filter
Enables statistical
processing on correct
weight.
Do not use in case of
dynamic weighing.
SECONDARY PARAMETERS
Capacity (Secondary)
Capacity
Range1 Capacity (Secondary)
Range1 Capacity
Range2 Capacity (Secondary)
Range2 Capacity
Division (Secondary)
Division
Unit of measurement
(Secondary)
Unit of measurement
FIELDS
Fields
Defines the number of weighing ranges into which the nominal
capacity of the instrument is divided.
It is possible to select: