86
DD1010 FLYNET
5.16
Testing a serial transmission
The indicator is able to send a data string to external devices. The available data strings are listed in
paragraph 5 on page 30.
Once the transmission has been configured, whether serial or network, it can be tested via PC. Then
connect the free end of the cable to the PC, using an adapter if necessary, and open a software
capable of handling incoming data traffic (example: Hyper Terminal). In case of serial connection, set
the reception data in the same way as they are set on the indicator (baud rate, stop bit). In case of
Ethernet connection, set the IP address of the indicator and the communication port entered in the
indicator configuration.
In case of cyclically transmitted string, when the connection to the indicator is activated, the data will
start to be displayed on the monitor. If the string is transmitted via remote commands, ACK NAK or
on request, send for example the string transmission start command (<SX>CR) to start the dialogue
between the devices; to end the dialogue send the string end command (<EX>CR).
Summary of Contents for DD1010
Page 2: ......