INSTALLATION MANUAL

ENGLISH

Thank you for buying this product, our company is sure that you will be more 
than satisfied with its performance.
This product is supplied with an “Instruction Manual” which should be read 
carefully as it provides important information about safety, installation, ope-
ration and maintenance. 
This product complies with recognised technical standards and safety regula-
tions. We declare that it is in conformity with the following European Directives: 
89/336/EEC, 73/23/EEC and subsequent amendments.

1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.

•   The  “

Warnings

”  leaflet  and  “

Instruction  booklet

”  supplied  with  this 

product should be read carefully as they provide important information 
about safety, installation, use and maintenance.

•   Scrap packing materials (plastic, cardboard, polystyrene etc) according 

to the provisions set out by current standards. Keep nylon or polystyrene 
bags out of children’s reach.

•   Keep  the  instructions  together  with  the  technical  brochure  for  future 

reference.

•   This  product  was  exclusively  designed  and  manufactured  for  the  use 

specified in the present documentation. Any other use not specified in 
this documentation could damage the product and be dangerous.

•   The Company declines all responsibility for any consequences resulting 

from  improper  use  of  the  product,  or  use  which  is  different  from  that 
expected and specified in the present documentation.

•   Do not install the product in explosive atmosphere.
•   The construction components of this product must comply with the following 

European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned 
standards as well as the current national standards should be respected 
in order to achieve a good safety level.

•   The Company declines all responsibility for any consequences resulting 

from failure to observe Good Technical Practice when constructing closing 
structures (door, gates etc.), as well as from any deformation which might 
occur during use.

•   The installation must comply with the provisions set out by the following 

European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent 
amendments.

•   Disconnect the electrical power supply before carrying out any work on 

the installation. Also disconnect any buffer batteries, if fitted.

•   Fit an omnipolar or magnetothermal switch on the mains power supply, 

having a contact opening distance equal to or greater than 3,5 mm.

•   Check that a differential switch with a 0.03A threshold is fitted just before 

the power supply mains.

•   Check that earthing is carried out correctly: connect all metal parts for 

closure (doors, gates etc.) and all system components provided with an 
earth terminal.

•   Fit all the safety devices (photocells, electric edges etc.) which are needed 

to protect the area from any danger caused by squashing, conveying and 
shearing.

•   Position at least one luminous signal indication device (blinker) where it 

can be easily seen, and fix a Warning sign to the structure.

•   The Company declines all responsibility with respect to the automation safety 

and correct operation when other manufacturers’ components are used.

•   Only use original parts for any maintenance or repair operation.
•   Do not modify the automation components, unless explicitly authorised 

by the company.

•   Instruct  the  product  user  about  the  control  systems  provided  and  the 

manual opening operation in case of emergency.

•   Do not allow persons or children to remain in the automation operation area.
•   Keep  radio  control  or  other  control  devices  out  of  children’s  reach,  in 

order to avoid unintentional automation activation.

•   The user must avoid any attempt to carry out work or repair on the automa-

tion system, and always request the assistance of qualified personnel.

•   Anything which is not expressly provided for in the present instructions, 

is not allowed.

•   Installation  must  be  carried  out  using  the  safety  devices  and  controls 

prescribed by the EN 12978 Standard.

2) GENERAL OUTLINE

ALCOR N mod. control unit has been designed to be applied on swing gates. 
It can control one or two operators.

3) TECHNICAL DATA

Power supply:  ..............................................................230V±10%, 50Hz(*)
Mains insulation/very low voltage:  ...................................> 4M

7

, 500V

Working temperature: ...............................................................  -10 / +55°C

Dielectric strength:….  ......................mains/low voltage 3750V~ for 1 minut
Maximum motor power ..........................................................1 motor 300W
................................................................................2 motors 300W + 300W
Supply to accessories:  .................................. 24V~, (0.2A max absorption)
Incorporated Rolling-Code radio receiver:  .............. Frequency 433.92MHz
Coding:  ..............................................Rolling-Code Algorithm to be cloned
No. combinations: .......................................................................... 4 milliard
Antenna impedance: ........................................................... 50Ohm (RG58)
Max no. radio transmitters to be memorised: ........................................... 63
Dimensions:  ..............................................................................see figure 1
(* other voltages available on request)

4) TERMINAL BOARD CONNECTIONS (Fig.2)

For the wiring diagram and the cable section, make reference to the ope-
rator’s manual.

WARNING 

– During the wiring and installation operations,  refer to the current 

standards as well as principles of good technical practice. 
Wires powered at different voltages must be physically separated, or suitably 
insulated with at least 1 mm extra insulation. The wires must be clamped by 
an extra fastener near the terminals, for example by bands.
All the connection cables must be kept at an adequate distance from the 
dissipator.
Connect the yellow/green conductor of the power supply cable to the earth terminal.
230V cables must be physically separate from the safety very low voltage circuits.
Keep the mains voltage connections definitely separate from the (24V) very 
low voltage connections.
The  capacitors  inside  the  control  unit  must  be  positioned  in  such  a  way 
as not to decrease the surface and air distances with respect to the safety 
very low voltage.

WARNING! For connection to the mains, use a multipolar cable with a 
minimum of 3x1.5mm

2

 cross section and complying with the previou-

sly mentioned regulations. For example, if the cable is out side (in the 
open), it has to be at least equal to H07RN-F, but if it is on the inside 
(or outside  but placed in a  plastic cable cannel) it has to be or at least 
egual to H05VV-F with section 3x1.5mm

2

.

1-2 

Power supply 230V +/- 10% 50/60 Hz (Neutral wire to terminal 1).

3-4-5  M1 motor connection (terminal 4 common wire, terminals 3-5 motor 

and capacitor operation).

1-4 

Blinker connection 230V

6-7-8  M2r motor connection (terminal 7 common wire, terminals 6-8 motor 

and capacitor operation).

1-7 

Electric lock connection 230V mod. EBP.

9-10  Input for START Button (N.O.).
9-11  Input for STOP Button (N.C.). If not used, leave bridged. 
9-12  Input for Photocell (N.C.). If not used, leave bridged.
9-13  Input with function selectable from DSW9:
 

 

with DSW9 OFF, Input for Opening Limit Switch (N.C.). If not used, 
leave bridged.   

 

 

with DSW9 ON Input for OPEN Button (N.O.).*

9-14  Input with function selectable from DSW9 and DSW10:
 

 

with  DSW9  OFF,  Input  for  Closing  Limit  Switch  (N.C.).  If  not  used, 
leave bridged.  

 

 

with DSW9 ON and DSW10 OFF, Input for CLOSE Button (N.O.).* 

 

 

with  DSW9  ON  and  DSW10  ON,  Input  for  PEDESTRIAN  Button 
(N.O.). The pedestrian command is active from gate fully closed; if the 
gate is not closed, the PEDESTRIAN button carries out the START 
functions.* 

15-16 Output 24V for accessory power supply 200mA MAX.
17-18 Output for second radio channel, N.O. contact (24V / 1A max.). If an 

external receiver is used, it must be a double-channel receiver.

 

 

A dry N.O. contact must be electrically connected to the terminals.

19-20 Input for receiver antenna (20 Braid, 19 Signal).
*With  operation  without  limit  switches,  the  motors  remain  active  for  the 
working time set.
RX  

Connector for the external receiver board.

5) LED

 (Fig.3)        

The  ALCOR  N  control  units  are  provided  with  a  series  of  self-diagnosis 
LEDs which control all the functions.

POWER:

 Led for power supply on.

OP:

    

Led  for  Signal  indication  of  Motors  active  on  Opening  /  Led  for 
Radio Programming.

CL:

   

Led for Signal indication of Motors active on Closing.

START:

  It comes on with the START command.

STOP:

  It goes off with the photocells not aligned or in the presence of 

obstacles.

SWO:

  

Led for signal indication of input 13 status: 

 

 

 

led on= input closed, led off= input open.

ALCOR N- 

9

D81

1509_01

Summary of Contents for ALCOR N

Page 1: ... DE USO Y DE INSTALACION INSTRUÇÕES DE USO E DE INSTALAÇÃO I GB F D E P QUADRO COMANDO CONTROL PANEL CENTRALE DE COMMANDE STEUERPLATINE CUADRO DE MANDOS QUADRO DE COMANDO Via Lago di Vico 44 36015 Schio VI Tel naz 0445 696511 Tel int 39 0445 696533 Fax 0445 696522 Internet www bft it E mail sales bft it ALCOR N 8 027908 297068 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 ...

Page 2: ...2 ALCOR N D811509_01 ...

Page 3: ...re tecnicamente costruttivamente e commercialmente il prodotto senza impegnarsi ad aggiornare la presente pubblicazione USER S MANUAL ENGLISH Thank you for buying this product our company is sure that you will be more than satisfied with the product s performance The product is supplied with a Warnings leaflet and an Instruction booklet These should both be read carefully as they provide important...

Page 4: ...chnique commercial et de construction sans s engager à mettre à jour cette publication BEDIENUNGSANLEITUNG DEUTSCH Wir danken Ihnen daß Sie sich für diese Anlage entschieden haben Ganz sicherwirdsiemitihrenLeistungenIhrenAnsprüchenvollaufgerechtwerden Lesen Sie aufmerksam die Broschüre Hinweisen und die Gebrauchsan weisung durch die dem Produkt beiliegen Sie enthalten wichtige Hinweise zur Sicherh...

Page 5: ...smodificacionesqueconsidereconvenientes para mejorar técnica constructiva y comercialmente el producto sin la obligación de poner al día esta publicación MANUAL PARA DE USO PORTUGUÊS Agradecendolhe pela preferência dada a este produto a Empresa tem a certeza que do mesmo obterá as prestações necessárias para o uso que entendefazer Leiaatentamenteoopúsculo Recomendações eo Manual de instruções que ...

Page 6: ... è permesso L installazione deve essere fatta utilizzando dispositivi di sicurezza e comandi comformi alla EN 12978 2 GENERALITÀ LacentralinaMod ALCORNèadattapercancelliabattente Puòcomandare uno o due operatori 3 DATI TECNICI Alimentazione 230V 10 50Hz Isolamento rete bassissima tensione 4M7 500V Temperatura di funzionamento 10 55 C Rigidità dielettrica rete bt 3750V per 1 minuto Potenza massima ...

Page 7: ...ensione della scheda il finecorsa di chiusura non è nè abilitato nè impegnato alla prima manovra non vengono eseguiti ne il colpo di ariete ne l apertura pedonale 7 REGOLAZIONE TRIMMER Fig 3 TCA DiP1 ON Regola il tempo di chiusura automatica trascorso il quale il cancello si chiude automaticamente regolabile da 1 a 120 sec TW Regola il tempo di lavoro dei motori trascorso il quale i motori si ferm...

Page 8: ... APRE CHIUDE PEDONALE configurazione DSW 9 ON utilizzare lo schema di figura 6A EBP fig 2 L elettroserratura a servizio continuo tipo EBP può essere collegata direttamente ai morsetti 1 e 4 14 DEMOLIZIONE Attenzione Avvalersi esclusivamente di personale qualificato L eliminazione dei materiali va fatta rispettando le norme vigenti Nel caso di demolizione non esistono particolari pericoli o rischi ...

Page 9: ... using the safety devices and controls prescribed by the EN 12978 Standard 2 GENERAL OUTLINE ALCOR N mod control unit has been designed to be applied on swing gates It can control one or two operators 3 TECHNICAL DATA Power supply 230V 10 50Hz Mains insulation very low voltage 4M7 500V Working temperature 10 55 C Dielectric strength mains low voltage 3750V for 1 minut Maximum motor power 1 motor 3...

Page 10: ...re neither the ram blow nor the pedestrian opening are carried out 7 TRIMMER ADJUSTMENT Fig 3 TCA Dip1 ON It is used to set the automatic closing time after which the gate closes automatically adjustable from 0 to 120 sec TW It is used to set the motor working time after which the motor stop adjustable from 1 to 90 sec When using electrical limit switches increase the motor stopping time by a few ...

Page 11: ...CRAPPING Warning This operation should only be carried out by qualified person nel Materials must be disposed of in conformity with the current regulations In case of scrapping the automation devices do not entail any particular risks or danger In case of materials to be recycled these should be sorted out by type electrical components copper aluminium plastic etc 15 DISMANTLING Warning this opera...

Page 12: ...res de la motorisation L utilisateur doit éviter toute tentative d intervention ou de réparation de la motorisation et ne doit s adresser qu à du personnel qualifié Tout ce qui n est pas expressément prévu dans ces instructions est interdit L installation doit être faite en utilisant des dispositifs de sécurité et des commandes conformes à la norme EN 12978 2 GÉNÉRALITÉS La centrale Mod ALCOR N es...

Page 13: ...on Entrées 13 14 Fin de course Touches ON Les entrées 13 et 14 sont programmées comme Entrée touches de commande Entrée 13 Touche d OPEN Entrée 14 selon la configu ration DSW 10 Les moteurs avec cette configuration restent actifs pendant le temps de travail programmé OFF Les entrées 13 et 14 sont programmées comme entrée si elles sont respectivement fins de course d Ouverture et de Fermeture DIP 1...

Page 14: ...de connecter une serrure électri que à 12V SS Fig 6 6A Carte en option voyant portail ouvert ATTENTION fonctionne uniquement si des fins de course électriques sont utilisées Avec les fins de course branchées configuration DSW 9 OFF utiliser le schéma de la figure 6 Avec les touches OUVRIR FERMER PIÉTON configuration DSW 9 ON utiliser le schéma de la figure 6A EBP fig 2 La serrure électrique à serv...

Page 15: ...ur entsprechend qualifizierte Fachleute sind hierzu befugt Alles was nicht ausdrücklich in dieser Anleitung genannt ist ist untersagt Die Installation muß mit Sicherheits und Steuerungsvorrichtungen vor genommen werden die der Norm EN 12978 entsprechen 2 ALLGEMEINES Das Steuerungsmodell ALCOR N ist für Flügelgittertore geeignet Es können damit ein oder zwei Antriebe gesteuert werden 3 TECHNISCHE D...

Page 16: ...nichtbenutztwerden FürdenAntriebvonSchiebetoren ist ihre Benutzung strengstens untersagt DIP 9 Funktionsauswahl Eingänge 13 14 Endtaster Knöpfe OFF ON Die Eingänge 13 und 14 sind als Eingang für Bedienknöpfe eingeri chtet Eingang 13 Knopf OPEN Eingang 14 je nach Stellung von DSW 10 Bei dieser Konfiguration laufen die Motoren für die vorgegebene Arbeitszeit weiter OFF Die Eingänge 13 und 14 sind al...

Page 17: ...troschlosses mit 12V SS Abb 6 6A Zusatzkarte Kontrollampe Tor offen ACHTUNG Funktioniert nur wenn die elektrischen Endtaster benutzt werden Bei angeschlossenen Endtastern Konfiguration DSW 9 OFF das Schema aus Abbildung 6 nutzen Mit den Knöpfen ÖFFNEN SCHLIESSEN FUSSGÄNGER Konfi guration DSW 9 ON das Schema aus Abbildung 6A benutzen EBP Abb 2 Das Elektroschloß des Typs EBP für einen kontinuierlich...

Page 18: ...e intervención o reparación del automatismo y dirigirse únicamente a personal cualificado Todo lo que no está expresamente previsto en estas instrucciones no está permitido La instalación debe realizarse utilizando dispositivos de seguridad y mandos conformes a la EN 12978 2 GENERALIDADES LacentralMod ALCORNesidóneaparacancelasbatientes Puedeaccionar uno o dos operadores 3 DATOS TECNICOS Alimentac...

Page 19: ...te IMPORTANTE Si no se han instalado topes mecánicos adecuados esta función no debe utilizarse Está absolutamente prohibida en la motorización de cancelas correderas DIP 9 Selección Función entradas 13 14 Fin de carrera Botones OFF ON Las entradas 13 y 14 están configuradas como Entrada para botones de mando Entrada 13 Botón de OPEN Entrada 14 según configu ración DSW 10 Con esta configuración los...

Page 20: ...ONIX 13 ACCESORIOS SPL fig 4 Tarjeta opcional de precalentamiento Aconsejada en caso de temperaturas inferiores a los 10 C En el caso de motores oleodiná micos ME fig 5 Tarjeta opcional que permite conectar una electrocerradura de 12 V SS Figs 6 6A Tarjeta opcional para indicador luminoso de cancela abierta ATENCION funciona únicamente si se utilizan los fines de carrera eléctricos Con los fines d...

Page 21: ...ler se unicamente de pessoal qualificado Tudo aquilo que não é expressamente previsto nestas instruções não é consentido A instalação deve ser efectuada utilizando dispositivos de segurança e comandos conformes à EN 12978 2 GENERALIDADES A central Mod ALCOR N é ideal para os portões de batente Pode comandar um ou dois operadores 3 DADOS TÉCNICOS Alimentação 230V 10 50Hz Isolamento rede baixíssima ...

Page 22: ...ra botões de comando Entrada 13 Botão de OPEN Entrada 14 segundo confi guração DSW 10 Com esta configuração os motores permanecem activos pelo tempo de trabalho definido OFF As entradas 13 e 14 estão definidas respectivamente como entrada de fim de curso de Abertura e de Fecho DIP 10 Selecção Função entradas botões de comando 13 14 N B Apenas com DSW 9 ON Com DSW 9 OFF a posição do DSW 10 não tem ...

Page 23: ...ma fechadura eléctrica a 12V SS Fig 6 6A Placa opcional luz indicadora de portão aberto ATENÇÃO funciona apenas se utilizam se os fim de curso eléctri cos Com os fim de curso ligados configuração DSW 9 OFF utilizar o esquema de figura 6 Com botões ABRE FECHA POSTIGO configuração DSW 0 ON utilizar o esquema da figura 6A EBP fig 2 A fechadura eléctrica de funcionamento contínuo tipo EBP pode ser lig...

Page 24: ...OP PHOT SWO N C OPEN N O SWO N C CLOSE PED N O 24V IIo RC 0V NO N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ANTENNA ANTENNE ANTENNA ANTENA ANTENNE M2r M1 L NC NC ALCOR N F o r i Ø 6 236 207 194 120 100 24 ALCOR N D811509_01 ...

Page 25: ...Fig 4 Fig 5 Fig 6 Fig 6A SWC N C ALCOR N ALCOR N ALCOR N ME SS ALCOR N SS SPL ALCOR N 25 D811509_01 ...

Page 26: ...tatos UNITRC UNIFLAT Contatti Contacts Contacts Kontakte Contactos Contatos UNIMITTO Contatti Contacts Contacts Kontakte Contactos Contatos Fig 4 Fig 7 P1 P1 T1 Led T2 P1 P1 T1 T2 T3 T4 P1 P1 1 3 4 1 2 2 3 4 UNIMITTO UNITRC P1 Contatti Contacts Contacts Kontakte Contactos Contatos 26 ALCOR N D811509_01 ...

Page 27: ...ALCOR N 27 D811509_01 ...

Page 28: ......

Reviews: