44 | Wi-Q™ Mercury Setup and User Guide
3 HARDWARE INSTALLATION
3 HARDWARE INSTALLATION
3.2.7.3 Troubleshooting the Controllers
3.2.7.3.1 Troubleshooting WDC and Omnilock Locks
If the mechanism doesn’t unlock, refer to the following table:
LED Lights
Sounder
Try
Single Red Flash --------
Use the card at a moderate
speed.
Red Flashes
3 short
tones
Use the temporary operator card
provided with the lock,
or
perform a deep reset to restore
to the factory default settings.
(The lock may already be associ-
ated/programmed.)
Green Flashes
--------
Check the motor connection on
the Omnilock.
Green and Red
Alternating
Flashes
--------
Check that the motor connection
is secured on the WDC at the
connector between the wiring
harnesses and at the controller
board.
• The magnetic stripe on the card should be aligned
with the “V” mark by the card slot. The lights on the
top of the controller will flash green once and unlock,
then during the open delay time, it will flash green five
times. Once this occurs, the card controller light will
flash red and lock.
3. While unlocked, check for proper lock operation.
Keypad Check
If the controller is a keypad type, perform the following steps:
WDC
1. At the keypad, enter the default Programmer-ID, 1234#.
The green light on top of the card controller will flash once
and the lock will unlock, then during the open delay time,
it will flash green five times. Once this occurs, the control-
ler red light will flash and the lock will relock.
2. While unlocked, check for proper lock operation.
OMW
1. At the keypad, enter the default Programmer-ID, 1234.
The green light on top of the card controller will flash once
and the lock will unlock, then during the open delay time,
it will flash green five times. Once this occurs, the control-
ler red light will flash and the lock will relock.
2. While unlocked, check for proper lock operation.