background image

Quadra II 24 C.A.I.

7

This  new  temperature  value  is  the  result  of  the  temperature  set 

manually  with  the  heating  water  temperature  selector  and  the 

increase of +10 °C of the S.A.R.A function. After the second cycle 

the temperature value should be kept at the set value +10°C until 

the request of the room thermostat is satisfied.

4.3 Switching off

Temporary switching off

In case of absence for short periods of time, set the mode selector 

(fig 6b) to   (OFF), the green LED flashes ON for 0.5 seconds, 

OFF for 3.5 seconds

.

In this way (leaving the electricity and fuel supplies enabled), the 

boiler is protected by the following systems:

-  

Anti-frost device:

  when  the  temperature  of  the  water  in  the 

boiler  falls  below  5°C,  the  circulator  and,  if  necessary,  the 

burner are activated at minimum output levels to bring the water 

temperature back to the values for safety (35°C). During the anti-

frost cycle, the symbol   appears on the digital monitor. 

-  

Circulator anti-blocking function:

 an operation cycle is 

activated every 24 hours.

Long period switching off

In case of absence for long periods of time, set the mode selector 

(fig 6b) to   (OFF), the green LED flashes ON for 0.5 seconds, 

OFF for 3.5 seconds.

Turn the main system switch OFF. Close the gas and water taps of 

the heating and domestic hot water system. In this case, anti-frost 

device is deactivated: drain the systems, in case of risk of frost.

4.4 Light signals and faults

The operating status of the boiler is shown on the digital display, 

below is a list of the types of displays.

To restore operation (deactivate alarms):

Faults A 01-02-03

Position the function selector to   (OFF), wait 5-6 seconds then 

set it to the required position   (summer mode) or 

 (winter 

mode). If the reset attempts do not reactivate the boiler, contact the 

Technical Assistance Centre.

Fault A04

In addition to the fault code, the digital display shows the symbol 

.

Check the pressure value indicated by the water gauge:

if it is less than 0.3 bar, position the function selector to   (OFF) 

and adjust the filling tap (

L

 - fig. 13) until the pressure reaches a 

value between 1 and 1.5 bar.

Then position the mode selector to the desired position   

(summer) or 

 (winter). 

If  pressure  drops  are  frequent,  request  the  intervention  of  the 

Technical Assistance Service.

Fault A06

The boiler operates normally but cannot reliably maintain a 

constant  domestic  hot  water  temperature,  which  remains  set  at 

around 50°C. Contact the Technical Assistance Centre.

Fault A07

Contact the Technical Assistance Centre.

4.5 Adjustments

The boiler has already been adjusted by the manufacturer.

If it is necessary to adjust it again, for example after extraordinary 

maintenance,  after  replacement  of  gas  valve  or  after  gas 

conversion, carry out the following procedure.

  The maximum output adjustment must be carried out in the 

sequence indicated exclusively by qualified personnel.

-  remove the shell unscrewing the fixing screws 

A

 (fig. 6)

-  unscrew  by  two  turns  the  screw  of  the  pressure  test  point 

downstream the gas valve and connecting the pressure gauge.

4.5.1 Maximum power and minimum domestic hot water 

adjustment

-  Fully open the hot water tap

-  On the control panel:

-  set the mode selector to 

 (summer) (fig. 2a)

- turn the domestic hot water temperature selector to its 

maximum (fig. 8a)

-  Power the boiler setting the system main switch to “on”

-  Check that the pressure on the pressure gauge is stable; or with 

a  milliammeter  in  series  to  the  modulator,  make  sure  that  the 

modulator supplies the maximum available current (120 mA for 

G20 and 165 mA for LPG).

-  Carefully prise out the protection cap of the adjustment screws, 

using a screwdriver (fig. 15)

-  With a fork spanner CH10 use the adjustment nut of the maximum 

output in order to obtain the value indicated in table "Technical 

data"

-  Disconnect the modulator faston

-  Wait  until  the  pressure  on  the  pressure  gauge  is  stable  at 

minimum value

-  Paying  attention  not  to  press  the  internal  shaft,  use  an  Allen 

spanner to turn the red adjustment screw for domestic hot water 

minimum temperature regulation, calibrating it until the pressure 

gauge reads the value indicated in the table "Technical data"

-  Reconnect the modulator faston

-  Close the domestic hot water tap

-  Carefully refit the protection cap of the adjustment screws.

BOILER STATUS

DISPLAY

RED LED

YELLOW LED

GREEN LED

TYPES OF 

ALARMS

Off status (OFF) 

OFF

flashing 0.5 on/3.5 off

None

Stand-by

-

flashing 0.5 on/3.5 off

Signal

ACF alarm lockout module

A01 

 

on

Definitive lockout

ACF electronics fault alarm
Limit thermostat alarm

A02 

flashing 0.5 on/0.5 off

Definitive lockout

Fumes thermostat alarm

A03 

on

Definitive lockout

Water pressure switch alarm

A04 

 

on

on

Definitive lockout

NTC domestic water fault

A06 

flashing 0.5 on/0.5 off

flashing 0.5 on/0.5 off

Signal

NTC heating outlet fault

A07 

on

Temporary stop

False flame

A11 

flashing 0.2 on/0.2 off

Temporary stop

Temporary pending ignition

flashing 0.5 on/0.5 off

Temporary stop

Water pressure switch intervention

flashing 0.5 on/0.5 off

Temporary stop

Calibration

flashing 0.5 on/0.5 off

flashing 0.5 on/0.5 off

Signal

Preheating active function

on

Signal

Preheating heat request

 

Signal

External probe presence

Signal

Domestic water heat request

60

°C 

Signal

Heating heat request

80

°C 

Signal

Antifreeze heat request

Signal

Flame present

on

Signal

Summary of Contents for quadra ii 24 C.A.I.

Page 1: ...Quadra II 24 C A I EN INSTALLER AND USER MANUAL PL INSTRUKCJA OBS UGI INSTALACJI I KONSERWACJI KOT A GAZOWEGO FR MANUEL D INSTALLATION ET D UTILISATION ES INSTRUCCIONES DE INSTALACI N Y USO RO MANUAL...

Page 2: ...n es techniques 31 Panneau de commande 52 l ments fonctionnels de la chaudi re 53 Circuit hydraulique 54 Sch mas lectriques 57 Pr valence r siduelle du circulateur 59 Kocio QUADRA II C A I spe nia pod...

Page 3: ...to Delegado UE N 811 2013 Reglamento Delegado UE N 813 2013 Reglamento Delegado UE N 814 2013 RO Centrala QUADRA II C A I este fabricat n conformitate cu cerin ele urm toarelor Directive Directiva gaz...

Page 4: ...zing boiler maintenance must be carried out at least once a year This should be booked in advance with the Technical Assistance Service For safety always remember that It is dangerous to activate elec...

Page 5: ...ailable this can be checked by the message on the packaging and the adhesive label indicating the gas type It is very important to highlight that in some cases the smoke pipes are under pressure and t...

Page 6: ...rescribed by current regulations 4 2 Appliance ignition To start up the boiler it is necessary to carry out the following operations power the boiler open the gas tap present in the system to allow fu...

Page 7: ...justed by the manufacturer If it is necessary to adjust it again for example after extraordinary maintenance after replacement of gas valve or after gas conversion carry out the following procedure Th...

Page 8: ...disassembly refer to instructions below remove power supply from the boiler and close the gas tap remove the components to access to the internal parts of the boiler fig 19 disconnect the spark plug c...

Page 9: ...t combustion For better use remember that a periodic external cleaning with soapy water not only improves its aesthetic aspect but also preserves panelling from corrosion extending its life cycle if t...

Page 10: ...e below 0 5 bar red field If this condition is checked it is necessary to restore water pressure in the boiler proceeding as follows set the mode selector 3 fig 1a to OFF turn on the filling tap L fig...

Page 11: ...e bar 0 15 Hot water quantity with t 25 C l min 13 7 with t 30 C l min 11 5 with t 35 C l min 9 8 DHW minimum output l min 2 Selection field of DHW temperature C 37 60 Flow regulator l min 10 Gas pres...

Page 12: ...ciency class C Water heating energy efficiency class B Rated heat output Pnominal 24 kW Seasonal space heating energy efficiency s 77 Useful heat output At rated heat output and high temperature regim...

Page 13: ...li zachodzi niebezpiecze stwo zamarzania konserwacj kot a nale y przeprowadza co najmniej raz w roku Us ug taka nale y rezerwowa z wyprzedzeniem w Autoryzowanym Serwisie Beretta Dla zapewnienia bezpie...

Page 14: ...a poniewa ka dy stan wstrzymania na przyk ad brak gazu zasilania elektrycznego b d blokada kot a wy cza zabezpieczenia MINIMALNE ODLEG O CI Aby umo liwi dost p do wn trza gazowego kot a grzejnego w ce...

Page 15: ...u 3 7 Nape nianie instalacji rys 13 Po przeprowadzeniu pod cze hydraulicznych mo na przyst pi do nape niania instalacji c o Ta czynno musi by przeprowadzona przy zimnej instalacji wykonuj c nast puj c...

Page 16: ...szenia temperatury zaprogramowanej r cznie prze cznikiem temperatury wody c o o 10 C przez funkcj S A R A Po drugim cyklu temperatura b dzie utrzymywana na poziomie wy szym o 10 C od zaprogramowanej...

Page 17: ...ym kotle i ustawieniu pokr t a trybu pracy w pozycji ZIMA przy braku dania grzania W czasie kiedy funkcja jest aktywna palnik jest w czony a kocio produkuje energi do c o Aby dokona regulacji post puj...

Page 18: ...takt z wykwalifikowanym personelem Kocio powinien by u ytkowany zgodnie z przeznaczeniem Wyklucza si wszelk odpowiedzialno producenta importera z powodu szk d wynikaj cych z b dnej instalacji regulacj...

Page 19: ...unkcyjny rys 6b w po o eniu OFF Regulacja temperatury wody grzewczej Do regulacji temperatury wody grzewczej nale y obr ci pokr t o z symbolem na terenie podzielonym na segmenty rys 2b Regulacja tempe...

Page 20: ...uk adu elektronicznego ACF Alarm termostatu ograniczaj cego A02 miga 0 5 w 0 5 wy Ca kowita blokada Przekroczenie temperatury spalin A03 W Ca kowita blokada Alarm prze cznika ci nienia wody A04 W W Ca...

Page 21: ...ilania gazu I2Lw G27 mbar 20 Ci nienie zasilania gazu I3P G31 mbar 37 Ci nienie zasilania gazu I3B P G30 G31 mbar 30 Po czenia hydrauliczne Wej cie wyj cie ogrzewania 3 4 Wej cie wyj cie c w u 1 2 Wlo...

Page 22: ...wa AFC 19 GJ w re imie wysokotemperaturowym temperatura wody powrotnej wynosi 60 C a wody zasilaj cej kocio 80 C w re imie niskotemperaturowym 30 C w przypadku kot w kondensacyjnych i 37 C w przypadku...

Page 23: ...le Service apr s vente pour effectuer au moins les op rations suivantes positionner l interrupteur principal de l appareil et l interrupteur g n ral de l installation sur off fermer les robinets du co...

Page 24: ...t rieur fig 2 La chaudi re est pourvue de protections qui garantissent son fonc tionnement correct avec une plage de temp rature de 0 C 60 C Pour b n ficier des protections l appareil doit tre en cond...

Page 25: ...es de danger Les ouvertures pour l air de combustion doivent tre r alis es conform ment la l gislation applicable En cas de formation de condensation le conduit d chappement doit tre isol La figure 12...

Page 26: ...Signaux lumineux et anomalies L afficheur num rique montre le code d anomalie d tect e fig 6a Fonction Syst me automatique de r glage de l ambiance S A R A fig 7a En pla ant le s lecteur de temp ratur...

Page 27: ...um l aided unecl en fourchette CH10 afin d obtenir la valeur indiqu e dans le tableau caract ristiques techniques d brancher le connecteur Faston du modulateur attendre ce que la pression lue sur le m...

Page 28: ...i dessous couper l alimentation lectrique de la chaudi re et fermer le robinet du gaz enlever les composants pour acc der aux parties internes de la chaudi re fig 19 d connecter le branchement du c bl...

Page 29: ...re s allume avec une lumi re verte fixe L cran num rique affiche la temp ra ture de l eau chaude l ic ne indiquant le chauffage et l ic ne flamme fig 3a En cas de demande d eau chaude sanitaire la ch...

Page 30: ...on sont fr quentes demander l intervention du service Technique Apr s vente Anomalie A06 La chaudi re fonctionne normalement mais ne garantit pas la sta bilit de la temp rature de l eau sanitaire qui...

Page 31: ...e bar 6 Pression minimale bar 0 15 Quantit d eau chaude avec t 25 C l min 13 7 avec t 30 C l min 11 5 avec t 35 C l min 9 8 Puissance minimum ECS l min 2 Plage de s lection de la temp rature ECS C 37...

Page 32: ...ominale Pnominale 24 kW Efficacit nerg tique saisonni re pour le chauffage des locaux s 77 Production de chaleur utile la puissance thermique nominale et en r gime haute temp rature P4 24 0 kW 30 de l...

Page 33: ...caldera al menos una vez al a o program ndola con antelaci n con el Servicio T cnico de Asistencia Desde el punto de vista de la seguridad se debe recordar que Es peligroso accionar dispositivos o apa...

Page 34: ...p rdidas por sobrepresi n de la instalaci n de calefacci n El circuito de agua sanitaria no necesita de una v lvula de seguridad pero debe asegurarse que la presi n del acueducto no supere los 6 bar...

Page 35: ...las siguientes instrucciones apagar la caldera aflojar la v lvula de vaciado de la caldera M vaciar los puntos m s bajos de la instalaci n 3 9 Vaciado del agua caliente sanitaria fig 13 Cada vez que e...

Page 36: ...C Al alcanzar el nuevo valor establecido comienza un conteo de otros 20 minutos Si durante este per odo el termostato ambiente continua solicitando calor el valor de la temperatura establecida aumenta...

Page 37: ...el ctrica se activa y desactiva nica mente desde el jumper JP1 fig 16 Los dos LED VERDE y ROJO parpadean simult neamente en el panel de control por 4 segundos aproximadamente La habilitaci n de la fun...

Page 38: ...as por medio de la llave situada en la caldera No limpiar el aparato o sus diferentes piezas con sustancias infla mables por ej bencina alcohol etc No limpiar los paneles las partes pintadas y las pie...

Page 39: ...de que haya una petici n de agua caliente sanitaria la caldera se enciende y el indicador LED de la caldera se enciende con una luz verde fija La pantalla digital exhibir la temperatura del sistema de...

Page 40: ...nstalaci n En este caso la funci n antihielo quedar desactivada Vaciar las instalaciones si hubiese riesgo de hielo 4A CONTROLES Asegurarse al comienzo de la estaci n de calefacci n y tambi n peri dic...

Page 41: ...Presi n m nima bar 0 15 Cantidad de agua caliente con t 25 C l min 13 7 con t 30 C l min 11 5 con t 35 C l min 9 8 ACS potencia m nima l min 2 Campo de selecci n de la temperatura H2O sanitaria C 37 6...

Page 42: ...ca de caldeo de agua B Potencia calor fica nominal Pnominal 24 kW Eficiencia energ tica estacional de calefacci n s 77 Potencia calor fica til A potencia calor fica nominal y r gimen de alta temperatu...

Page 43: ...i ap at t pe circuitul de nc lzire c t i pe cel de ap cald menajer golirea instala iei termice i menajere dac exist riscul de nghe ntre inerea centralei se va face minim o dat pe an program nd din ti...

Page 44: ...nat corespunz tor pentru preluarea dilat rii apei din circuitul de preparare a apei calde menajere n instala iile unde presiunea re elei de alimentare cu ap dep e te valoarea de 3 bar ca urmare a posi...

Page 45: ...etta nainte de a porni centrala veri ca i ca a caracteristicile re elelor de alimentare energie electric ap gaz s corespund datelor de pe pl cu a tehnic b tuburile care ies din central s e acoperite c...

Page 46: ...onarea solicita i interven ia Centrului de Service Autorizat Anomalia A04 Pe l ng codul de anomalie pe display este afi at i simbolul Verifica i valoarea presiunii indicate de termomanometru dac este...

Page 47: ...Gas conversion operations Conversia de la un tip de gaz la altul este simpl i se poate face i cu centrala instalat Centrala este livrat din fabric pentru func ionarea cu gaz metan G20 conform celor in...

Page 48: ...nterzis orice interven ie asupra elementelor sigilate Nu acoperi i i nu reduce i gurile de aerisire ale nc perii n care este instalat centrala Gurile de aerisire sunt vitale pentru o ardere corect Pen...

Page 49: ...ecunde aprins 3 5 secunde stins n acest mod l s nd active alimentarea electric i alimentarea cu combustibil centrala este protejat de sistemele Anti nghe atunci c nd temperatura apei din central scade...

Page 50: ...7 la un debit de l h 1 000 Vas de expansiune cu membran l 8 Presarcin vas de expansiune bar 1 ACM Presiune maxim bar 6 Presiune minim bar 0 15 Cantitate de ap cald cu t 25 C l min 13 7 cu t 30 C l min...

Page 51: ...re nominal Prated 24 kW Randamentul energetic sezonier aferent nc lzirii incintelor s 77 Puterea termic util La puterea termic nominal i regim de temperatur ridicat P4 24 0 kW La 30 din puterea termic...

Page 52: ...gulaci n de la temperatura agua sanitaria Funci n precalentamiento agua caliente m s r pido 5 Led Descripci n de los iconos Carga de la instalaci n este icono se visualiza junto con el c digo de la an...

Page 53: ...Transformator zap onu 6 Elektroda jonizacyjno kontrolna 7 Palnik 8 Termostat granicznej temperatury 9 Sonda NTC na c o 10 Termostat spalin 11 Wymienni ciep a 12 Naczynie wzbiorcze 13 Odpowietrznik au...

Page 54: ...incalzire 2 Intrare ACM 3 Intrare ACM 4 Tur nc lzire 5 Robinet umplere 6 Supap de siguran 7 By pass 8 Robinet anti retur 9 Robinet de golire 10 Presostat ap 11 Sond NTC ACM 12 Sond NTC nc lzire 13 Sch...

Page 55: ...pacitate termic Pn Putere termic IP Grad de protec ie Pmw Presiune maxim de func ionare circ menajer Pms Presiune maxim nc lzire T Temperatur Randament D Capacitate specific NOx Clas NOx EN SERIAL NUM...

Page 56: ...indica en el diagrama despu s de quitar el puente en el conector de 2 v as CN5 T A Jumper de termostato ambiente contacto libre de tensi n B Los dispositivos de baja tensi n deben conectarse al conect...

Page 57: ...rrone blu 2 1 3 5 4 1 2 4 3 OPE OPE rosa blu P marrone N L 230 V M3 F blu blu marrone marrone marrone blu MOD 1 12 CN11 F L viola viola rosso rosso t S S bianco bianco P A 2 3 1 grigio grigio MOD 1 4...

Page 58: ...on B Vanne de gaz C Fusible ext rieur 3 15A F D CN6 si n cessaire MP Carte de commande avec affichage num rique et transformateur d allumage int gr P1 Potentiom tre pour s lectionner off t hiver r ini...

Page 59: ...evalen rezidual disponibil Aminti i v c instala ia func ioneaz corect dac n schimb torul de c ldur circularea apei se face n mod corect eficient n acest scop cazanul este dotat cu un by pass automat c...

Page 60: ...fig 3 EN measurement in mm PL Wymiary w mm FR mesures en mm ES medidas en mm RO m suri n mm EN Indoor installation PL Instalacja w pomieszczeniu FR Installation l int rieur ES Instalaci n en el interi...

Page 61: ...oom thermostat PL B bezpiecznik C Zasilanie 230V T A termostat pokojowy FR B Fusible C Alimentation T A Thermostat d ambiance ES B Fusible C Alimentaci n T A Termostato ambiente RO B Rezisten C Alimen...

Page 62: ...al maxim nc lzire JP3 Punte selectare MTN GPL A JP1 JP2 JP3 JP4 JP5 JP6 CN8 CN7 1 12 CN11 1 4 CN10 1 7 CN9 CN6 CN5 CN12 1 F1 2A T CN13 P1 P3 P2 CN4 1 3 CN3 1 2 CN2 1 6 TR1 FA1 Elettrodo A R MP PL JP1...

Page 63: ...A R A Function PL F S Funkcja S A R A FR F S Fonction S A R A ES F S Funci n S A R A RO F S Func ie S A R A fig 1a fig 5b fig 8a AUTO F S fig 6a red LED Czerwona dioda LED LED rouge Led rojo Led ro u...

Page 64: ...ttaboilers com www berettaboilers com In order to improve its products Beretta reserves the right to modify the characteristics and information contained in this manual at any time and without prior n...

Reviews: