76
Operation
IPG-3901 Gateway Config Panel
IPG-3901 Gateway Config Panel
In the context of a Kaleido-Modular-X system with KMX-3901-IN-IP input/output cards, you
must configure a stream addresses, and select a signal format for each input or output
gateway you choose to enable on the IPG-3901 modules. These settings are available on
the IPG-3901 module’s
Gateway Config
panel, under the
Gateways
tab. You may need to
consult your network administrator.
Determine how many input and output gateways you need, and then clear the check box,
in the
En.
column, for every gateway you do
not
wish to use. For example, if you do not wish
to stream the mosaic output at all, clear the check boxes for both MV OUT 1 and MV OUT 2,
or, if two input gateways can handle the number of streams you wish to monitor, then clear
the check boxes for the remaining input gateways.
Select an enabled MV IN or MV OUT gateway, by clicking anywhere in the corresponding
row. In the editing area at the bottom of the panel, enter the appropriate stream address
and port number, and select the appropriate signal format. Click
Apply
to set these values
Note:
The current version of the KMX-3901-IN-IP card supports a maximum
of 6 HD input streams.