![Belden Grass Valley GV Korona User Manual Download Page 48](http://html1.mh-extra.com/html/belden/grass-valley-gv-korona/grass-valley-gv-korona_user-manual_2725633048.webp)
48
Suite Preferences
Patch a Key Input from Another Source
• Menu Name (Menu Name column)—Source will appear with this name in the
menus only.
To change the source patching, select an Engineering/Fixed source to be associated with
the currently selected Logical source with the Engineering Source data pad or by scrolling
the Engineering Source IDs Button pane.
Enable Source Correction on any Source (Globally)
Using Source Corrections, in the User Setups, Source Patch menu (or the Source Corrections
menu), you can enable source correction for a patched Engineering to Logical source. The
source correction is global; anywhere the patched source is mapped on the switcher.
Source Correction is saved as part of File Ops, User Setups, Suite Prefs and can be
included/excluded.
1 Choose the source and enable Source Correction:
a In the User Setups, Suite Prefs, Source Patch menu, select the Enable button to the
right of the desired Source Patch row, or
b In the Source Correction menu, select the Logical Name data pad and enter the
Logical ID in the pop-up keypad then turn on the Source Correction Enable button.
2 Adjust the parameters for Video Processing and RGB Color Correction in the Source
Correction menu.
Patch a Key Input from Another Source
You can patch a key from a different source using Patch Key.
1 Select
User Setup
,
Suite Prefs
,
Source Patch
.
2 Select the data entry pad in the Patch Key column for the Logical ID you wish to patch a
key from a different source.
3 Select the Eng or Fixed source in the Sources scrolling list containing the key you wish
to patch (LOGO KEY in the example) or press the Patch Key Source ID data pad and
enter the Source ID number for the key you wish to patch, and press
Enter
.
The key signal for Logical ID 19 (LOGO KEY) is now paired with the Logical ID 16 (RED VID)
video signal.
Note:
Enabled Source Correction on a source is not supported by
E-MEM, however patching a source on an M/E, from the Source
Corrections menu is supported.
Note:
The same Engineering source can have Source Correction enabled
or disabled by patching the source to a different logical ID.
Example:
There are three shows with three different video sources
over the same key signal, in this case the station logo. The three logos
are defined as RED LOGO, BLU LOGO, and GRN LOGO in the menus
and as RLGO, BLGO, and GLGO in the Panel Name which will be
displayed on the OLEDs of the keyer source select buttons when
assigned to the Control Panel.
Summary of Contents for Grass Valley GV Korona
Page 16: ...xvi Table of Contents Index 425 Contact Us 433...
Page 32: ...32 Introduction Supported Control Protocols...
Page 40: ...40 Panel Preferences Map Remote Aux Panel Delegation Buttons Logical Mapping...
Page 61: ...61 Kayenne Karrera GV Korona User Manual Update a Show File 1 Select File Ops Show Files...
Page 72: ...72 Suite Preferences Load User Setups...
Page 266: ...266 Device Control Newton Channel Information...
Page 432: ...432 Index...