Air Connections: Air Panel to H2AIR® Top Flip Cylinder
1) Run a field supplied
1/4” poly-flow airline from the Main Air Supply to the Main Air Connection on
the Air Panel. See the image below.
2) Run a field supplied
1/4” poly-flow airline from the extend regulator on the Air Panel to the extend
port on the Top Flip Cylinder. See the images above and below.
3) Run a field supplied
1/4” poly-flow airline from the retract regulator on the Air Panel to the retract
port on the Top Flip Cylinder. See the images above.
Retract Regulator Connection
1/4” Poly-Flow Tube to the Retract
Port on the Cylinder
120 VAC Output from
the Site Controller
Main Air Connection
1/4” Poly-Flow Tube
Extend Regulator Connection
1/4” Poly-Flow Tube to the
Extend Port on the Cylinder
4-Way Air Valve
Field Supplied
1/4" Poly Flow Tube
Route as necessary
Field Supplied 1/4" Poly
Flow Tube from the
Main Pneumatic Source
@100 psi Air Flow Min.
Extend Port
Air Panel
Retract Port
Extend Port
Retract Port
Each port on the Cylinder
has a flow control valve to
adjust the cylinder actuation
speed.
The Cover was removed
from the Top Flip to see the
ports on the Cylinder.