Control 1.3 Swimming Pool Control Unit
Operation
33
6.4.3.7
ECO Functions
You need to go to the
Treatment
ECO Function
submenu to set the ECO functions. This is shown in
Figure 8.
Floor valve: defines whether a floor valve is connected The floor valve is automatically activated
when the roller shutter is closed and water is therefore drawn in through the floor drain.
Cover: defines the speed of the filter pump when the roller shutter is closed
Figure 8: ECO functions
The limit switches of the roller shutter must be connected to the terminals E8.
The floor valve must be connected to the output A10.
6.4.3.8
Lowering Valve
The function of the lowering valve cannot be changed in the control unit. The terminal of the lowering valve
is only controlled for overflow pools. The terminal can be used as a freely programmable terminal for
skimmer pools.
The lowering valve is automatically activated as soon as there is an input signal on the input E8 (roller
shutter closed). The lowering valve is supplied with continuous voltage (230 V) for the time during which the
roller shutter is closed.
WARNING!
Make sure that the roller shutter does not come into contact with the pool shell when the
lowering valve is activated (lower water level in the pool). In case of contact, there is a
risk of property damage when opening the roller shutter!
The lowering valve must be connected to terminal A8.