Control 1.3 Swimming Pool Control Unit
Operation
35
Figure 9: Auxiliary heating
The water sensor (PT1000) must be connected to the terminals E4.
The heating pump/heating solenoid valve must be connected to the terminals A3 (230 V).
The release signal for the heating must be connected to the terminals A12.
6.4.4.2
Solar Mode
You need to go to the
Warming
Solar Mode
submenu to set the solar mode. This is shown in Figure
10. The following parameters can be set:
-
Sensor: defines whether a solar sensor is available. The solar heating function can be called up only
if a sensor is available. If a solar sensor is available, its temperature values are displayed on the
start screen.
-
Solar: defines whether the solar heating function (solar pump and collector) should be used to warm
up the water temperature.
-
Temperature: defines the target value of the swimming pool water in solar mode
-
Valve time: defines the pause time for adjusting the solar valve. The filter pump is switched off for
this time.