Control 1.3 Swimming Pool Control Unit
Operation
36
-
Difference: defines the minimum required temperature difference between the solar and swimming
pool water temperature to activate the solar mode.
-
Forced: defines whether the filter pump must be switched on for solar operation outside of the
switching times.
-
Running time: defines the minimum running time of the solar mode
-
Speed: defines the speed at which the filter pump should run in solar mode
Figure 10: Solar mode
The solar sensor/collector sensor (PT1000) must be connected to the terminals E5.
The collector pump must be connected to the terminals A2 (230 V).
A rod valve/solenoid valve can be connected to the terminals A17 (potential-free switch, max 3 A) to
activate the collector line. Voltage must be applied to the terminal for this purpose.
6.4.4.3
Sensor Calibration
You need to go to the
Warming
Sensor Calibration
submenu to set the sensor deviation. The value
entered is added to the measured value. A negative correction value must be entered if the measured