Commissioning and Configuration
EP8309-1022
65
Version: 2.0.0
EP8309 100 Hz dither with 10 % amplitude,
poor parameterization (5 ms/div)
Green: Set current
Red: Actual current
EP8309 100 Hz dither with 10 % amplitude,
better parameterization (5 ms/div)
Green: Set current
Red: Actual current
5.6
Range settings for inputs and outputs
CoE-Online tab
The
CoE-Online
tab lists the contents of the slave object directory of the slave (SDO upload) and enables
the user to modify the content of an object in this list.
Object
contains the range settings for the inputs and outputs of channels 1 to 4.
Fig. 61: CoE-Online tab
Click on objects 0xF800:01 to 0xF800:04 to change the settings.