Product Overview
EP8309-1022
14
Version: 2.0.0
Tacho single-shaft mode (depending on the setting in the PDO assignment)
The data for the tacho input can be found under
TACHO Single Shaft
Mode Input Channel 1
.
see data under commissioning
Tacho dual-shaft mode (depending on the setting in the PDO assignment)
The data for the tacho input can be found under
TACHO Dual Shaft
Mode Input Channel 1 or 2
.
see data under commissioning
DIG Inputs
The data for the digital inputs can be found under
DIG Inputs
.
X4 Pin4 -> socket 4, pin 4
....
PWM Status
The data for the PWM output can be found under
PWM Status
DEV Inputs
The diagnostic data for the two voltages Us and Up can be found under
DEV Inputs
.
TRUE = voltage <= approx. 18 V
DC
....
TACHO Output Channel 1
The control data for the tacho input can be found under
TACHO Output
Channel 1
.
Reset Error - error reset