Remote Annex 6300 Supplement to the Remote Annex Administrator’s Guide for UNIX
Chapter 11 Internetwork Packet Exchange (IPX) Protocol
A-156
Book A
The
DISABLED MODULES
field displays any software modules that
have been disabled via the RA 6300 disabled_modules parameter.
(See
disabled_modules
on page C-51.) If this field displays
ipx
, then
IPX is unavailable even if the IPX option_key parameter is set
correctly.
2.
Set the option_key parameter to the value you obtained in Step 1.
In the following example, the option key is set to
RaqbDwv8e
using
admin:
annex: su
Password:
annex# admin
Annex administration Remote Annex Rx.x, 72 ports
admin: set annex option_key RaqbDwv8e
The option_key value is case-sensitive.
The default superuser password for the RA 6300 is its
IPX node.
3.
Specify the type of IPX frame that the Novell network uses to
encapsulate IPX packets on the Ethernet.
To specify the frame type, set the RA 6300 ipx_frame_type
parameter. Valid values are ethernetII, raw802_3 (the default),
802_2, or 802_2snap. The following command sets the type
to 802_2:
admin: set annex ipx_frame_type 802_2
To determine the frame type the network is using, check the
AUTOEXEC.NCF file on your Novell server or use the Novell file
server console command called PROTOCOL.
4.
Reboot the RA 6300 to put the parameter settings into effect:
admin: q
annex# boot