Remote Annex 6300 Supplement to the Remote Annex Administrator’s Guide for UNIX
Chapter 6 Point-to-Point Protocol (PPP)
A-100
Book A
•
Set the allow_compression parameter to Y if you want the
RA 6300 to accept compressed packets.
•
Use the supplied defaults for the data_bits (8), stop_bits (1),
and parity (none) parameters.
PPP is an 8-bit protocol. If data_bits is set to 7, and parity
is not set to none, the Remote Annex forces the data_bits
setting to 8 and the parity setting to none. Otherwise, the
RA 6300 syslogs an error message.
•
Set the address_origin parameter to acp so that the RA 6300
requests the endpoint addresses, based on the user’s login,
from ACP.
•
You can leave ppp_mru parameter set to its default.
Sample Configuration for Addressing Using
Asynchronous Port Parameters
Figure A-6
illustrates a configuration in which a single remote PC is
connected to an Annex through an asynchronous PPP session. The session
is running via a BRI line with a V.120 terminal adapter and the PRI line
to the Annex.
Summary of Contents for 6300
Page 4: ...Remote Annex 6300 Supplement to the Remote Annex Administrator s Guide for UNIX iv ...
Page 20: ...Remote Annex 6300 Supplement to the Remote Annex Administrator s Guide for UNIX Figures xx ...
Page 24: ...Remote Annex 6300 Supplement to the Remote Annex Administrator s Guide for UNIX Tables xxiv ...