Measurement
Description
Unit
EHC–05
SCB-10
CM060
Current Pump speed of zoneCIRCA0 and CIRCA1
%
X
CM061
Current Pump speed of zone CIRCB1
%
X
CM062
Current Pump speed of zoneDHW and DHW1
%
X
CM063
Current Pump speed of zone CIRCC1
%
X
CM064
Current Pump speed of zone CIRCAUX1
%
X
CM120
Zone Current Mode:
0 =Scheduling
1 =Manual
2 =Antifrost
3 =Temporary
/
X
X
CM121
Zone Current ModeCIRCA0 and CIRCA1
/
X
CM122
Zone Current Mode CIRCB1
/
X
CM123
Zone Current ModeDHW and DHW1
/
X
CM124
Zone Current Mode CIRCC1
/
X
CM130
Current activity of the zone:
0 =Anti frost
1 =Reduced
2 =Comfort
3 =Anti legionella
/
X
X
CM131
Current activity of the zoneCIRCA0 and CIRCA1
/
X
CM132
Current activity of the zone CIRCB1
/
X
CM133
Current activity of the zoneDHW and DHW1
/
X
CM134
Current activity of the zone CIRCC1
/
X
CM190
Wished room temperature setpoint of the zoneCIRCA0
and CIRCA1
°C
X
X
CM191
Wished room temperature setpoint of the zone CIRCB1 °C
X
CM192
Wished room temperature setpoint of the zoneDHW
and DHW1
°C
X
CM193
Wished room temperature setpoint of the zone CIRCC1 °C
X
CM194
Wished room temperature setpoint of the zone CIR
CAUX1
°C
X
CM210
Current Outside Temperature of the zoneCIRCA0 and
CIRCA1
°C
X
X
CM212
Current Outside Temperature of the zone CIRCB1
°C
X
CM213
Current Outside Temperature of the zoneDHW and
DHW1
°C
X
CM214
Current Outside Temperature of the zone CIRCC1
°C
X
CM252
Measure of Tank Domestic Hot Water Top temperature
of the zone DHW1
°C
X
Tab.78 Available values: DM = Direct Hot Water Measures = Measured values for the domestic hot water tank
Measurement
Description
Unit
EHC–05
DM000
Dhw Tank Electrical backup operation
/
X
DM001
Domestic Hot Water tank temperature (bottom sensor)
°C
X
DM006
Domestic Hot Water tank temperature (top sensor)
°C
X
DM009
Automatic/derogation status of Domestic Hot Water mode:
0 =Scheduling
1 =Manual
2 =Antifrost
3 =Temporary
°C
X
DM029
Domestic Hot Water temperature setpoint
°C
X