6.3.2
Fitting the assembly rail
1. Drill 2 holes with a diameter of 6 mm.
Important
Extra holes are provided in case one or other of the standard
locating holes prevents the correct location of the plug.
2. Put the plugs in place.
3. Fix the mounting rail to the wall using the hexagonal head screws
provided for this purpose. Set the level using a spirit level.
6.3.3
Mounting the module on the wall
1. Position the indoor module above the mounting rail so that it rests
snugly against it.
2. Gently lower the indoor module.
6.4
Putting the outdoor unit in place
6.4.1
Allowing sufficient space for the outdoor unit
Minimum distances from the wall are necessary in order to guarantee
optimum performance.
Fig.15
MW-1001197-1
2
3
1
3
557.
5
ø1
0
457
.5
Fig.16
MW-1001198-1
6 Installation
24
iHPI
7701563 - v02 - 22052018