11‐11
Icon
Parameter
Function/Action
Range Of
Value
Default
Value
35
Sequin size
R1
Sets the Sequin Size Change on Right side
0-50
0
36
Network Type
Not Used
------- -----
37
Marker Type
Laser Marker operation
1: Turns ON when the machine is not sewing.
2: Turns On only in “Drive mode” and not sewing.
3: Same as above item 1 + it resets to ON
when the machine is powered ON.
4: Same as above item 2 + it resets to ON
when the machine is powered ON.
This feature is for DT/VT only.
1-4 1
38
Borer 2
Switches off the thread break detector of a needle
fitted with a boring device. Enter the number of
the needle that has the borer. Set to 0 if a boring
device is not in use.
0 – 15
[Needles]
0
39
Borer 3
Switches off the thread break detector of a needle
fitted with a boring device. Enter the number of
the needle that has the borer. Set to 0 if a boring
device is not in use.
0 – 15
[Needles]
0
40
Sequin size
L2
Sets the Sequin Size Change on Left side
0-50
0
41
Sequin size
R2
Sets the Sequin Size Change on Right side
0-50
0
42
Marker Type
Presser foot function control
0: Not used.
1: Changes Presser foot height by the Needle
number.
2: Changes the Presser foot height by the
PR function code in the color change F-list.
0-2 0
Summary of Contents for BEXS
Page 1: ...B E X S Instruction Manual ...
Page 12: ...1 7 Warning Labels Contents Hook Warning Label Belt Warning Label ...
Page 18: ...3 2 1 Appearance and Components ...
Page 19: ...3 3 ...
Page 186: ...Embroidery Machine BEXR BEXS BEXY series Mechanical Guide ...
Page 194: ...1 6 X Series Mechanical Guide ...
Page 196: ...1 8 X Series Mechanical Guide ...
Page 199: ...X Series Mechanical Guide 1 11 ...
Page 201: ...X Series Mechanical Guide 1 13 ...
Page 233: ...13 1 Trade Marks WindowsTM is the trademark of the Microsoft Inc ...