No.
DTC name
Text 1
Corrective
action
Text 2
ISO 14229
P-Code
J1939-73
Detection item
Remark
Behavior During
Malfunction
Recovery from
error
SPN
FMI
64
CAN2 Bus off
See Service
Manual
U0075
523547 2
CAN2 +B or GND
short circuit or
high traffic error
- Insufficient
output
- Transmitted
CAN data are
invalid
Key switch turn
OFF
65
CAN-KBT
Frame error
See Service
Manual
U0081
523548 2
CAN-KBT original
frame open circuit
error
- Insufficient
output
Key switch turn
OFF
66
Intake air temp.
built-in MAF
sensor: Low
See Service
Manual
P0072
171
4
Ground short
circuit of sensor
or harness
None
Diagnostic
counter = zero
67
Intake air temp.
built-in MAF
sensor: High
See Service
Manual
P0073
171
3
Open circuit or +B
short circuit of
sensor or harness
None
Diagnostic
counter = zero
68
Intake air
volume: Low
See Service
Manual
P0101
132
1
Engine inlet air
mass flow rate
lacking
(Disconnect turbo
blower intake
hose)
- Insufficient
output
Key switch turn
OFF
70
MAF sensor:
High
See Service
Manual
P0103
132
3
+B short circuit of
sensor or harness
Engine is not
stopped forcibly
by ECU
However
KUBOTA strongly
recommends
operator to stop
engine as soon
as possible
- Insufficient
output
- Worsening
exhaust gas
emissions
Key switch turn
OFF
71
EGR actuator
open circuit
See Service
Manual
P0403
523574 3
EGR actuator
open circuit
- Insufficient
output
- Worsening
exhaust gas
performance
Key switch turn
OFF
72
EGR actuator
coil short
See Service
Manual
P0404
523574 4
EGR actuator coil
short
- Insufficient
output
- Worsening
exhaust gas
emissions
Key switch turn
OFF
73
EGR position
sensor failure
See Service
Manual
P0409
523572 4
EGR position
sensor failure
- Insufficient
output
- Worsening
exhaust gas
emissions
Key switch turn
OFF
74
Exhaust gas
temperature
sensor 1: Low
See Service
Manual
P0543
3242
4
Ground short
circuit of sensor
or harness
None
Key switch turn
OFF
GM2810A
Appended Table
Page 8-20
List of Fault Codes