No.
DTC name
Text 1
Corrective
action
Text 2
ISO 14229
P-Code
J1939-73
Detection item
Remark
Behavior During
Malfunction
Recovery from
error
SPN
FMI
5
Fuel leak (in
high pressured
fuel system)
Stop ENG
See Service
Manual
P0093
1239
1
consumption is
found)
To minimize PM
emission to DPF
- Insufficient
output
- Worsening
exhaust gas
emissions
- Engine stops in
some cases
Key switch turn
OFF
6
Intake air temp.
error: Low
See Service
Manual
P0112
172
4
Ground short
circuit of sensor
or harness
- White smoke
increases at low
temperature
Diagnostic
counter = zero
7
Intake air temp.
error: High
See Service
Manual
P0113
172
3
Open circuit or +B
short circuit of
sensor or harness
- White smoke
increases at low
temperature
Diag counter =
zero
8
Coolant
temperature
sensor: Low
See Service
Manual
P0117
110
4
Ground short
circuit of sensor
or harness
- White smoke
increases at low
temperature
- Insufficient
output
- Worsening
exhaust gas
emissions
Key switch turn
OFF
9
Coolant
temperature
sensor: High
See Service
Manual
P0118
110
3
Open circuit or +B
short circuit of
sensor or harness
- White smoke
increases at low
temperature
- Insufficient
output
- Worsening
exhaust gas
emissions
Key switch turn
OFF
10
Rail pressure
sensor: Low
Stop ENG
See Service
Manual
P0192
157
4
Ground short
circuit of sensor
or harness
Failure of sensor
To minimize PM
emission to DPF
- Insufficient
output
- Worsening
exhaust gas
emissions
- Engine running
noise increases
- White smoke
increases
- Engine stops
Key switch turn
OFF
Appended Table
GM2810A
Appended Table
Page 8-13
List of Fault Codes