9. Service Mode
Set up the network configuration.
To set up the network configuration, follow the next procedure :
1. Push the cursor key
↑
or
↓
to highlight
Network Configuration
. (menu 9-20)
2. Press
ENTER
to display the network configuration menu. (menu 9-21)
3. Set DHCP on or off (contact your network responsible for the correct setting in your environment).
DHCP on
DHCP server assigned an IP address to the client (network projector).
DHCP off
the client has to fill out the IP address, the subnet mask and the default gateway.
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
NETWORK
LAMP
MORE...
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 9-20
NETWORK CONFIGURATION
DHCP [ON]
IP ADDRESS 158.150.160.200
SUBNET MASK 158.150.160.201
DEFAULT GATEWAY
158.150.300.300
MAC ADDRESS 01:01:02:DB:FF:89
APPLY
Select with
↑
or
↓
<ENTER> to edit
Reprogram with
↑
or
↓
or numeric keys
APPLY to confirm
<EXIT> to return
Menu 9-21
Entering the necessary addresses.
1. Select the IP address with the cursor keys. (menu 9-22)
2. Press
ENTER
to edit.
3. Enter or reprogram the address with the numeric keys (contact your network responsible for the correct address).
An address contains 4 octets with a maximum value of 255, separated by a bullet.
4. Repeat the above steps for the subnet mask and the default gateway.
5. Select
APPLY
and press
ENTER
to install the entered addresses.
If a wrong value for an octet is entered, the following error message will be displayed to indicate where the error is located.
Example of message : "Invalid octet. The maximum value is 255 for each octet ! " . (menu 9-23)
NETWORK CONFIGURATION
DHCP [ON]
IP ADDRESS 158.150.160.200
SUBNET MASK 158.150.160.201
DEFAULT GATEWAY
158.150.300.300
MAC ADDRESS 01:01:02:DB:FF:89
APPLY
Select with
↑
or
↓
<ENTER> to edit
Reprogram with
↑
or
↓
or numeric keys
APPLY to confirm
<EXIT> to return
Menu 9-22
ERROR
Invalid octet
the maximum value is
255 for each octet!
<EXIT> to return.
Menu 9-23
9.9 Lamp
Lamp information light output switching
All information about the lamp is stored inside the lamp house and can be displayed via the projector software on the projection
screen. No information can be changed.
The Constant light output function can be changed between OFF, [slave] and [master].
Linked CLO
The constant light output of projectors in a chain (maximum 12 projectors) can be set to the same value by linking the projectors via
the RS232 connector.
To the RS232in of the first projector, a terminator must be connected (
Z3498823
). The out of the first must be connected to the in
of the next projector, etc.
96
R5976483 BARCOSLM R6 17092002
Summary of Contents for BARCOSLM R6
Page 1: ...BARCOPROJECTION BARCOSLM R6 R9001901 OWNERS MANUAL 17092002 R5976483 01 ...
Page 4: ......
Page 8: ...Table of contents 4 R5976483 BARCOSLM R6 17092002 ...
Page 13: ...2 Packaging and Dimensions Image 2 4 Top view dimensions R5976483 BARCOSLM R6 17092002 9 ...
Page 14: ...2 Packaging and Dimensions 10 R5976483 BARCOSLM R6 17092002 ...
Page 28: ...3 Installation Guidelines 24 R5976483 BARCOSLM R6 17092002 ...
Page 40: ...4 Connections 36 R5976483 BARCOSLM R6 17092002 ...
Page 82: ...7 Random Access Adjustment Mode 78 R5976483 BARCOSLM R6 17092002 ...
Page 106: ...9 Service Mode 102 R5976483 BARCOSLM R6 17092002 ...
Page 108: ...10 Programmable Function Keys 104 R5976483 BARCOSLM R6 17092002 ...
Page 112: ...A Standard Source set up Files 108 R5976483 BARCOSLM R6 17092002 ...