• Put a ceramic wool blanket with a thickness of at least 5 cm on the top of the
appliance and the sides and back of the appliance.
• Keep approximately 10 cm free of insulation material between the front of the
appliance and the front of the fireplace. This space is needed for the build of the
fireplace.
8.10
Build the fireplace
Caution:
• Refer to section
for clearances to flammable and non-flammable
materials.
• Refer to section
for applicable insulating plates.
• Make sure that brickwork is build with a clearing of at least 3 mm between
the sides and top of the appliance and the brickwork. The appliance can
expand during operation due to heating.
Note:
• Make sure the thickness of any plastering is taken into account when the
brickwork is being build.
• Do not use masking tape on the appliance. Masking tape damages the
paint on the appliance.
• If you use other material than bricks, install the material in accordance with
the instructions of the supplier of the material
• If you use other material than bricks, refer to the instructions of the supplier
of the used material for information on the need to use a mantle iron.
1.
Identify the positions where the fitting boxes of the ventilation air inlet and the
ventilation air outlet must be put. Refer to section
for requirements on the size of
the ventilation air openings.
2.
If the appliance has an Opti-Air system, make sure to put the room temperature
measurement cable and the battery holder in the correct position. Refer to section
and section
.
3.
If applicable, identify the positions where the fitting boxes of the convection air inlets
and convection air outlets must be put. Refer to
distances from ceiling and neighboring wall.
4.
Build the brickwork around the appliance up to the upper frame around the glass.
a) Install the fitting boxes of the ventilation air inlets.
b) Put the end of the NTC temperature measurement cable in the fitting box of one
of the ventilation air inlets. Make sure the ventilation air flows around the end of
the NTC temperature cable.
c)
If applicable, install the fitting boxes of the convection air inlets.
5.
If applicable, install a mantle iron to support the brickwork above the appliance. Put
the mantle iron on both sides of the brickwork. Maintain a space of at least 3 mm
between the appliance and the mantle iron.
6.
If applicable, install the flexible aluminum pipes of the convection set. Refer to
section
7.
Build the fireplace around the appliance.
a) Install the fitting boxes of the ventilation air outlets.
b) If applicable, install the fitting boxes of the convection air outlets
8.
Install the frame around the appliance.
Installation in a new fireplace
Cuatro-7 75-60
39
Summary of Contents for Cuatro-7 75-60
Page 6: ...1 Declaration of performance Declaration of performance 6 Cuatro 7 75 60...
Page 56: ...11 2 Connections on Opti Air system Technical data 56 Cuatro 7 75 60...
Page 59: ...12 Dimensions 12 1 Cuatro 7 75 60 with built in frame Dimensions Cuatro 7 75 60 59...
Page 60: ...12 2 Cuatro 7 75 60 with built in frame and convection casing Dimensions 60 Cuatro 7 75 60...
Page 66: ...12 8 Cuatro 7 75 60 with classic frame Dimensions 66 Cuatro 7 75 60...
Page 67: ...12 9 Cuatro 7 75 60 with classic frame and convection casing Dimensions Cuatro 7 75 60 67...
Page 75: ...Warranty Terms Cuatro 7 75 60 75...
Page 76: ...Your Barbas dealer 001 28 06 2022 352574 271 001...