8.8
Connect the convection set (optional)
1.
On the convection air box select one
of the 2 inlet openings, identified by
FAN, on the left or right side.
2.
Remove 1 break out plate in the
selected convection air inlet opening
with a hammer.
3.
Put the collar adaptor in the open
inlet opening (1).
4.
Bend out the 3 lips on the collar
adaptor (2) and turn the adapter until
it locks.
5.
Connect a flexible aluminum pipe (C)
on the collar adaptor . Use a hose
clamp (B).
6.
Connect the flexible aluminum pipe to a fitting box in the chimney breast
The convection air outlet can go via the front of the appliance and/or the top of the
appliance.
• Outlet of the convection air at the front of the appliance: refer to section
• Outlet of the convection air on top of the appliance: Refer to section
.
1
2
2
A
B
C
B
C
Installation in a new fireplace