5.6
Clearances to a non-flammable ceiling
Put a non-flammable insulation plate (false ceiling) of minimum 5 cm thickness at a height
of minimum 50 cm above the appliance.
Obey the dimensions mentioned in the tabel hereunder.
A
h
H
3
5
4
1
2
B
1
Chimney enclosure
2
Convection air outlet opening
3
Non-Flammable ceiling
4
Insulation plate (false ceiling)
5
Insulation plates
Dimensions
h
Area of the convection air outlet opening
Minimum 300 cm
2
H
Height of the false ceiling
Minimum 5 cm (= thickness false ceiling)
A
Distance between convection air outlet
opening and ceiling
Minimum 50 cm
Clearances