6
Installation requirements
6.1
Requirements on the installation of the appliance in an
existing fireplace
This section refers to the installation of the appliance in an existing open (masonry)
fireplace.
• Make sure that the location agrees with the safety requirements. Refer to section
• Make sure the opening in the fireplace is large enough for a gap of 1 - 3 cm between
the appliance and the inner fireplace walls .
• Make sure the floor can support the weight of the appliance. Refer to section
for the
weight of the appliance.
• Make sure that the floor temperatures in front of the appliance cannot be higher than
85 °C, during use of the appliance. Refer to section
• The non-combustible floor in front of the appliance must have a width that extends at
least 150 mm from each side of the appliance and a minimum depth in front of the
appliance according the requirements in section
.
• Make sure the room where the appliance is installed is properly ventilated.
• Make sure that combustion air can flow into the appliance without obstruction.
• If applicable, install a valve in the external combustion air pipe.
6.2
Requirements on the installation of the appliance in a new
fireplace
• Make sure the floor is made of concrete or a solid pedestal of nonflammable material.
• Make sure that the floor temperatures under and in front of the appliance are
maximum 85 °C, during use of the appliance. Refer to section
and section
• Make sure that the location agrees with the safety requirements. Refer to section
.
• Do not install the appliance against a combustible rear wall or combustible side wall.
• Make sure to obey the clearances as listed in section
• Make sure the floor can support the weight of the appliance. Refer to section
for the
weight of the appliance.
• Make sure the room where the appliance is installed is properly ventilated.
• Make sure that combustion air can flow into the appliance without obstruction.
• If applicable, install a valve in the external combustion air pipe.
• If the appliance is equipped with the optional convection ventilator, the combustion air
must be supplied from outside through a flexible aluminum pipe to the appliance.
• Make sure there is an earthed wall socket for the power supply of the convection
ventilator and an earthed wall socket with for the power supply of the Opti-Air system.
These sockets must be accessible at all times.
• Make sure the distance between the convection air outlet openings and the ceiling
above is at least 50 cm.
• Make sure the distance between the convection air outlet openings and a neighboring
wall is at least 20 cm.
Installation requirements
Cuatro-7 75-60
27
Summary of Contents for Cuatro-7 75-60
Page 6: ...1 Declaration of performance Declaration of performance 6 Cuatro 7 75 60...
Page 56: ...11 2 Connections on Opti Air system Technical data 56 Cuatro 7 75 60...
Page 59: ...12 Dimensions 12 1 Cuatro 7 75 60 with built in frame Dimensions Cuatro 7 75 60 59...
Page 60: ...12 2 Cuatro 7 75 60 with built in frame and convection casing Dimensions 60 Cuatro 7 75 60...
Page 66: ...12 8 Cuatro 7 75 60 with classic frame Dimensions 66 Cuatro 7 75 60...
Page 67: ...12 9 Cuatro 7 75 60 with classic frame and convection casing Dimensions Cuatro 7 75 60 67...
Page 75: ...Warranty Terms Cuatro 7 75 60 75...
Page 76: ...Your Barbas dealer 001 28 06 2022 352574 271 001...