3.6.3
Combustion levels in combination with a convection ventilator
The Opti-Air system in combination with a convection ventilator has 5 combustion levels
to choose from. Each combustion level is a combination of pre-defined thermal output
and pre-defined ventilator speed.
Combustion level
Thermal output
Ventilator speed
1
Minimum
Off
2
Minimum
Minimum
3
Nominal
50% of maximum speed
4
Nominal
Maximum
5
Maximum
Maximum
3.6.4
Combustion levels without a convection ventilator
The Opti-Air system without a convection ventilator has 3 combustion levels to choose
from. Each combustion level is a pre-defined thermal output.
Combustion level
Thermal output
1
Minimum
2
Nominal
3
Maximum
3.6.5
Combustion modes
During operation at a chosen combustion level the combustion process goes through 5
different combustion modes, each with its own pre-programmed combustion
characteristics. During the combustion process one of these combustion modes is active
dependent on the temperature in the combustion chamber.
Combustion mode
Description
1
Standby
The appliance is off and ready for use.
2
Firing up
Start of the appliance with the first load of wood logs. The
appliance heats up.
3
Burning
The appliance is at operating temperature. The actual
temperature can differ from the temperature setpoint, but
the Opti-Air system tries to control the temperature toward
the setpoint by changing the position of the combustion air
valves.
4
Refill
The appliance has cooled down, a reload with wood logs
is necessary.
5
Cooling down
The appliance was not reloaded with fuel within 45 mi-
nutes after Refill notice . Cooling downmode is active.
Note:
With the Barbas Opti-Air system it is not possible to manually control
the amount of combustion air into the appliance.
Description
Cuatro-7 75-60
15
Summary of Contents for Cuatro-7 75-60
Page 6: ...1 Declaration of performance Declaration of performance 6 Cuatro 7 75 60...
Page 56: ...11 2 Connections on Opti Air system Technical data 56 Cuatro 7 75 60...
Page 59: ...12 Dimensions 12 1 Cuatro 7 75 60 with built in frame Dimensions Cuatro 7 75 60 59...
Page 60: ...12 2 Cuatro 7 75 60 with built in frame and convection casing Dimensions 60 Cuatro 7 75 60...
Page 66: ...12 8 Cuatro 7 75 60 with classic frame Dimensions 66 Cuatro 7 75 60...
Page 67: ...12 9 Cuatro 7 75 60 with classic frame and convection casing Dimensions Cuatro 7 75 60 67...
Page 75: ...Warranty Terms Cuatro 7 75 60 75...
Page 76: ...Your Barbas dealer 001 28 06 2022 352574 271 001...