10.6.7
Install the lower baffle
Only do this procedure after finish of the procedure in section
.
1.
Make sure the glass fibre cord is in
the correct position in the cord holder
before the baffle is put back in the
appliance . Replace a damaged cord
with a new glass fibre cord with a
diameter of 14 mm.
2.
Move the lower baffle under an angle
into the combustion chamber (1).
3.
Move the baffle up under an angle
and put the right side of the baffle
above the cast iron side panels (2).
4.
Put the rear side of the baffle against
the rear wall (3).
5.
Move the left side of the lower baffle
up and put it on top of the cast iron
side panels on the left. If it does not
fit, make sure the cast iron side
panels are firmly seated agianst the
side wall of the appliance.
6.
Make sure the lower baffle is
horizontal and against the rear wall.
1
2
3
Maintenance
Cuatro-7 75-60
51