Non-flammable spacer
2
Non-flammable insulation plate
3
Flammable or load-bearing wall
Item
Dimension
A
Air gap
2.5 cm
B
Thickness plate
10 cm
C
Air gap / Spacer
2.5 cm
D
A+B+C
15 cm
E
B+C
12.5 cm
F
Minimum 3 mm clearance between appliance and surrounding construction
5.3
Clearance to flammable floor (under the appliance)
Put a non-flammable insulation plate with a minimum thickness of 3 cm under the
appliance. To avoid damage to this non-flammable plate, put ceramic or steel tiles
(approx. 10 x 10 cm) under the feet of the appliance.
5.4
Clearances to flammable ceiling
Note:
If a wooden beam is present above the appliance, make sure to protect it
against direct heat radiation. Make sure to put a non-flammable insulation
plate with a thickness of minimum 3 cm between the wooden beam and the
appliance. with an air gap of minimum 1 cm between the insulation plate and
the wooden beam.
Clearances
Cuatro-7 75-60
21
Summary of Contents for Cuatro-7 75-60
Page 6: ...1 Declaration of performance Declaration of performance 6 Cuatro 7 75 60...
Page 56: ...11 2 Connections on Opti Air system Technical data 56 Cuatro 7 75 60...
Page 59: ...12 Dimensions 12 1 Cuatro 7 75 60 with built in frame Dimensions Cuatro 7 75 60 59...
Page 60: ...12 2 Cuatro 7 75 60 with built in frame and convection casing Dimensions 60 Cuatro 7 75 60...
Page 66: ...12 8 Cuatro 7 75 60 with classic frame Dimensions 66 Cuatro 7 75 60...
Page 67: ...12 9 Cuatro 7 75 60 with classic frame and convection casing Dimensions Cuatro 7 75 60 67...
Page 75: ...Warranty Terms Cuatro 7 75 60 75...
Page 76: ...Your Barbas dealer 001 28 06 2022 352574 271 001...