5.7
Clearances in front of the appliance
Caution:
Do not put flammable items within minimum 180 cm radius from the
appliance.
B
A
A
1
C
2
1
Non-flammable floor plate
2
Appliance
A
Minimum 15 cm from the sides of the appliance.
B
Floor plate. Refer to the graph hereunder for the required minimum depth. This mini-
mum depth is dependent on the installation height of the appliance.
C
Minimum 180 cm clearance from the front of the appliance.
Put a non-flammable floor plate with a minimum thickness of 12 mm in front of the
appliance above a flammable floor. The minimum horizontal depth of the floor plate is
dependent on the vertical distance between the bottom of the appliance and the floor.
The graph shows the required minimum depth of the floor plate in relation to the
installation height.