Electronic Ignition Flame Control 

System Safety Manual 

Available in “Hi/Lo” and “On/Off” Models

 

 

      

 

 

 

    

Installation & Operation Instructions 

                                                Commercial and Residential Use

 

 

 

 

 

 

         

 

 

 

 
 
 

                  

       

 

 

 

   WARNING: FOR OUTDOOR USE ONLY 

 

        WARNING   
     •Improper installation, adjustment, alteration, service or maintenance can cause injury or property 
damage. Read the installation, operating and maintenance instructions thoroughly before installing or 
servicing this equipment. 
 
          WARNING 

   

•Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other 

appliance. 
   •An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. 
 
 
             DANGER 

     

If you smell gas: 

 

1) Shut off gas to appliance. 

 

2) Extinguish any open flame. 

 

3) If odor continues, keep away from appliance and immediately call gas supplier or fire  

     

 

    department. 

 

 
 

 
 
 
 
 

Select Models 

Certified to 

ANSI Z21.97-2014 

CSA 2.41-2014 

 

Installation 

We suggest that our products be 
installed by professionals that are 
locally licensed by the authority having 
jurisdiction in gas piping.   

 

INSTALLER: 

Leave this 

manual with the appliance. 

    CONSUMER: Retain this 

manual for future reference. 

 

Record and keep for your records: You may 
remove the label from the package and tape here. 
 
Model #: 
 
Serial #: 
 
BTU:                              Voltage: 

 

Attention: 

Hi/Lo Only 

For the App, the default 

security code is 2345

Summary of Contents for Electronic Ignition Flame Control System

Page 1: ...ammable vapors and liquids in vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues keep away from appliance and immediately call gas supplier or fire department Select Models Certified to ANSI Z21 97 2014 CSA ...

Page 2: ... 3 When not in use ensure power is off to the product to avoid accidental start up of the product 4 Product is for use with electrical remote timer control Do not use with gas remote timer controls WARNING Not for use with any kind of automatic start up timer WARNING We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas pip...

Page 3: ...ustibles 36 48 Overhead clearance above product 84 Noncombustible screen only Select a location above ground with good drainage and allows easy access for installation and maintenance of the fire pit Pick a location that allows sufficient horizontal room to enjoy the fire pit while allowing a safe distance from the heat and flame 3 Construction of the Enclosure WARNING For electronic ignition mode...

Page 4: ... Connections Use only joint compound or tape that is resistant to all gases Apply joint compound to all male pipe fittings only DO NOT use on FLARED fittings Be sure to tighten every joint securely WARNING For systems with an extended or detached valve box the area in which the valve box is installed must conform to all installation requirements to include but not limited to location construction ...

Page 5: ...r alter the product configuration 18 Set fire pit in properly constructed enclosure Section 3 19 Verify correct operation and lighting 20 Review safety manual with end user and instruct not to change modify fire pit or media 21 Leave manual with end user IMPORTANT On electronic ignition models please apply the Start Up and Shutdown decal next to control switch in an obvious position 5 Media WARNIN...

Page 6: ...r blowout box vents or opening with lava rock or glass Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner ignition Decorative Glass Application 1 Install your fire pit per instructions 2 Fill Pan with glass Cover burner with 1 8 to of glass Do not over fill with glass All LP installations must be checked for back pressure with media installed...

Page 7: ... mixer size as described below 40K Standard 127LC for use with HPC 6 Round 36 T and smaller 90K Standard 127 for use with HPC 12 Round 12 square 48 T and larger 150K Properly Sized 127 for use with HPC 18 Round 72 T and larger 300K Properly Sized 127 or 127HC with HPC 30 Round and larger Sizing recommendations is based on HPC burners only Installer is responsible for correct sizing based on the ap...

Page 8: ...d should be aligned with a burner hole as shown above Care must be taken to prevent flame from being blown under the pilot assembly and damaging wire or connections Water in Valve Prevention HPC does not cover water in the valve under warranty WARRANTY REQUIREMENT Fire Ring Drainage If the unit will or may be exposed to rain snow or moisture the installer must account for how water will drain out ...

Page 9: ...tes before going into lockout To reset turn OFF power then back ON again 3 Pilot flame will ignite and warm thermocouple it may take 30 seconds at times for thermocouple to get hot If thermocouple is not hot in 60 seconds system will shutdown then go back to Step 1 4 Once thermocouple is hot main valve will open allowing main burner to ignite 5 If pilot flame is blown out at anytime system will sh...

Page 10: ... and on to reset To correct overheating ensure enclosure has adequate ventilation see Construction of Enclosure 9 Maintenance WARNING Any guard or protective device removed for servicing must be replaced prior to operating the fire pit WARNING We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute NFI as NFI Gas Specialists WARNI...

Page 11: ...pressure Section 1 2 Small Pilot Flame Remove pilot head and clean orifice Section 8 3 Dirty Thermocouple Clean using soft brush Section 8 4 Fire Ring Obstructed Confirm no debris or water in ring Always cover fire pit 5 Improperly applied Media See Section 5 Main Burner Turning Off On Frequently 1 Small Pilot Flame Remove pilot head and clean orifice Section 8 2 Improperly applied Media See Secti...

Page 12: ...HPC labor The defective product must be sent back to HPC with a Return Merchandise Authorization RMA issued by HPC for that specific product and any other additional information for the nature of the defect or warranty claim The warranty does not cover items that have been damaged by overheating modification abuse or improper storage Also any labor involving installation or maintenance with the un...

Page 13: ...13 8 17 2016 850 EI ...

Page 14: ...14 8 17 2016 850 EI ...

Page 15: ...ect to the fire pit Setting up the App 1 Download the HPC Fire App from the Apple store or Google Play 2 Ensure that there is power supplied to the fire pit Note If power is already applied disconnect and reconnect power 3 Open the HPC Fire App see Fig 1 4 From the setup screen enter 6 characters 5 Enter a password and confirm the password 6 Select your language and press Continue 7 Enable the Blu...

Page 16: ...Flame HIGH LOW Timer amount of time left before shut off Troubleshoot Guide tap the link to online help Setup 1 Timer ON OFF and set the timer 2 Customize the fire pit s name 3 Customize the security code Igniter Indicator Temperature Indicator Timer amount of time left before shutoff Website link to HPCFire com ...

Page 17: ...17 8 17 2016 850 EI ...

Page 18: ...18 8 17 2016 850 EI ...

Page 19: ...19 8 17 2016 850 EI ...

Reviews: