1.3.14.7 System failure error codes
An incorrect configuration or defective hardware can cause a system failure error. The error code is indicated by
the red Error LED using four switch-on phases. The switch-on phases are either 150 ms or 600 ms. Error code
outputs are repeated cyclically after 2 seconds.
Legend
• ...
150 ms
- ...
600 ms
Pause ...
2 s delay
Error description
Error code indicated by red status LED
RAM error
(1)
•
•
•
-
Pause
•
•
•
-
Pause
Bus error
(2)
-
•
•
•
Pause
-
•
•
•
Pause
(1)
The module is defective and must be replaced.
(2)
The module or a system component is defective and must be replaced.
1.3.14.8 POWERLINK interface
POWERLINK 1 and POWERLINK 2
Interface
Pinout
Pin
Ethernet
1
RxD
Receiving data
2
RxD\
Receiving data\
3
TxD
Sending data
4
Termination
5
Termination
6
TxD\
Sending data\
7
Termination
Application interface
POWERLINK
1
Shielded RJ45 port
8
Termination
Note:
When transferring the SDC task, SDC is inactive (making SDC_SetTime inactive as well).
•
The POWERLINK interface card triggers a reset of the frequency inverter.
•
In order for the frequency inverter to be configured correctly again, the POWERLINK interface
card must be reset.
This interrupts the bus communication, and the CPU goes into service mode if "Module supervised
= on".
For this reason, transferring the project when "Module supervised = on" is only possible in service
mode.
Summary of Contents for 8I84T200037.01P-1
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...