2.8.9.3 Configuration of the analog inputs and the input "Pulse input"
The minimum and maximum input values (in volts, mA, etc.) are converted to % in order to adapt the references
to the application.
Minimum and maximum input values:
The minimum value corresponds to a reference of 0% and the maximum value to a reference of 100%. The mini-
mum value may be greater than the maximum value:
Reference
100 %
0 %
[Min value]
(
CrLx
or
Ulx
or
PIL
)
[Max value]
(
CrHx
or
Uhx
or
PFr
)
20 mA or
10 V or
30.00 kHz
Current,
Voltage
or frequency
input
For bidirectional inputs (±), the min. and max. are relative to the absolute value, for example, +/- 2 to 8 V.
The negative minimum value of the pulse input:
Reference
100%
0%
-30.00 kHz
[Min value]
(PIL)
[Max value]
(PFr)
30.00 kHz
Frequency
Input
Area (output values): Only for analog inputs
With this parameter, the reference range is set to [0% → 100%] or [-100% → 100%]. This will result in bidirectional
output from unidirectional input.
Reference
100%
0%
[Min value]
Range 0%
100%
➙
[Max value]
20 mA
or 0 V
Current
or voltage
Input
Summary of Contents for 8I84T200037.01P-1
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...