![B&R 8I84T200037.01P-1 User Manual Download Page 178](http://html1.mh-extra.com/html/bandr/8i84t200037-01p-1/8i84t200037-01p-1_user-manual_460473178.webp)
Programming guidelines
178
ACOPOSinverter P84 User's Manual 2.10
[CONFIGURATION R2] (r2)
Code
Name/Description
Setting range
Factory settings
r2-
[R2 CONFIGURATION]
r2
[R2 CONFIGURATION]
[No]
(nO)
Identical with R1 (
see "R1 CONFIGURATION" on page 176
) with the following addition (display only for information purposes, as is selection can
only be configured from the
[APPLICATION FCT.]
(Fun-)
menu):
bLC
[BRAKE LOGIC]
(bLC)
: Control braking contactor
LLC
[Line contactor assign]
(LLC)
:Control line contactor
OCC
[Mot. cont.]
(OCC)
: Control downstream motor contactor
EbO
[End wind.]
(EbO)
: End of winding ("Traverse control" function)
tSY
[Sync Wobble]
(tSY)
: Synchronization "counter wobble"
dCO
[DC load]
(dCO)
: Control pre-charge contactor DC bus
r2d
[R2 Delay time]
0 to 60000 ms
1)
0
For the assignments
[no fault]
(FLt)
,
[BRAKE LOGIC]
(bLC)
,
[Mot. cont.]
(OCC)
,
[DC load]
(dCO)
and
[Assign line cont]
(LLC)
the delay is
not adjustable and remains at 0.
The status change is only effective after the configured time as soon as the information is TRUE.
r2S
[R2 Active at]
[1]
(POS)
Configuration of the function logic:
POS
[1]
(POS)
: State 1 when the information is TRUE.
nEG
[0]
(nEG)
: State 0 when the information is TRUE.
For the assignments
[no fault]
(FLt)
,
[BRAKE LOGIC]
(bLC)
,
[DC load]
(dCO)
and
[assign line cont]
(LLC)
the configuration
[1]
(POS)
cannot
be changed.
r2H
[R2 Holding time]
0 to 9999 ms
0
For the assignments
[no fault]
(FLt)
,
[BRAKE LOGIC]
(bLC)
,
[DC load]
(dCO)
and
[assign line cont]
(LLC)
the hold time is not adjustable
and remains at 0.
The status change is only effective after the configured time as soon as the information is UNTRUE.
1)
0 to 9999 ms then 10.00 to 60.00 s on the integrated display terminal.
Summary of Contents for 8I84T200037.01P-1
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...