Installation guide
ACOPOSinverter P84 User's Manual 2.10
47
Model number
8I84T400075.01P-1
8I84T400150.01P-1
8I84T400220.01P-1
8I84T400300.01P-1
Input impedance
Voltage
30 kΩ
Current
242 Ω
Relay outputs
Quantity
2
Nominal voltage
30 VDC / 250 VAC
Switching capacity
Min.
3 mA for 24 VDC
Max.
With resistive load (cos φ = 1
and L/R = 0 ms)
2 A for 250 VAC or 30 VDC
With inductive load (cos φ = 0.4
and L/R = 7 ms)
1.5 A for 250 VAC or 30 VDC
Design
Relay 1
1 NO contact and 1 NC contact with a common point
Relay 2
1 NO contact
Response time (max.)
<7 ms ±0.5 ms
Electrical isolation
Output - ACOPOSinverter
Yes
Output - Output
No
Analog outputs
Quantity
1
Output
0 to 10 V or 0 to 20 mA
8)
Electrical isolation
Output - ACOPOSinverter
Yes
Output - Output
No
Max. load impedance
Voltage
470 Ω
Current
500 Ω
Update time
<2 ms ±0.5 ms
Resolution
10-bit
Operating conditions
Installation at elevations above sea
level
0 to 1000 m
Degree of protection per EN 60529
Upper part: IP21 and IP41
Lower part: IP54 (heat sink)
Ambient temperature
-10 to 50°C
Max. ambient temperature
Up to 60°C
Relative humidity per IEC 60068-2-3
5 to 95%, non-condensing
No dripping water
Maximum installation elevation
Up to 3000 m
9)
Max. pollution degree per IEC/EN
61800-5-1
2 (non-conductive pollution)
Environmental conditions per IEC
60721-3-3
Class 3C1 and 3S2
Operating position
Vertical mounting orientation ±10%
Environmental conditions
Temperature
Storage
-25 to 70°C
Vibration
Operation
3 to 13 Hz: 1.5 mm amplitude / 13 to 200 Hz: 1 g
Shock
Operation
15 g, 11 ms
Mechanical characteristics
Dimensions
Width
130 mm
155 mm
Height
230 mm
260 mm
Depth
175 mm
187 mm
Weight
3 kg
4 kg
Table 15: 8I84T400075.01P-1, 8I84T400150.01P-1, 8I84T400220.01P-1, 8I84T400300.01P-1 - Technical data
1)
Shield plate included in delivery
2)
For shielded motor cables
≤10 m → At a clock frequency of 4 kHz
≤5 m → At a clock frequency of 4.1 to 16 kHz
3)
For shielded motor cables
≤50 m → At a clock frequency of 4 kHz
≤20 m → At a clock frequency of 4.1 to 16 kHz
4)
For shielded motor cables
≤100 m → At a clock frequency of 4 kHz
≤50 m → At a clock frequency of 4.1 to 16 kHz
5)
These values are valid for the rated clock frequency.
6)
The min. resistance value is specified at a temperature of 20°C.
Summary of Contents for 8I84T200037.01P-1
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...