www.balluff.com
23
Mifare
Balluff data
carrier type
Manufac-
turer
Description
Memory
capacity
Usable
bytes with
CRC
Memory
type
BIS M-1_ _-01
NXP
Mifare Classic
752 bytes
658 bytes
EEPROM
BIS M-1_ _-10
NXP
Mifare Classic
736 bytes
644 bytes
EEPROM
Note
Data carriers cannot be used with BIS M-4_ _-0_ _-401-…, read/write devices.
ISO15693
Balluff data
carrier type
Manufac-
turer
Description
Memory
capacity
Usable
bytes with
CRC
Memory
type
BIS M-1_ _-02
Fujitsu
MB89R118
2000 bytes
1750 bytes
FRAM
BIS M-1_ _-03
NXP
SL2ICS20
112 bytes
98 bytes
EEPROM
BIS M-1_ _-04
Texas Inst.
TAG-IT Plus
256 bytes
224 bytes
EEPROM
BIS M-1_ _-05
Infineon
SRF55V02P
224 bytes
196 bytes
EEPROM
BIS M-1_ _-06
EM
EM4135
288 bytes
252 bytes
EEPROM
BIS M-1_ _-07
Infineon
SRF55V10P
992 bytes
868 bytes
EEPROM
BIS M-1_ _-08
NXP
SL2IC553
160 bytes
140 bytes
EEPROM
BIS M-1_ _-09
NXP
SL2ICS50
32 bytes
28 bytes
EEPROM
BIS M -1_ _ -11* Balluff
BIS M-1
8192 bytes
7168 bytes
FRAM
BIS M -1_ _ -13* Balluff
BIS M-1
32768 bytes
28672 bytes
FRAM
BIS M -1_ _ -14* Balluff
BIS M-1
65536 bytes
57344 bytes
FRAM
BIS M -1_ _ -15* Balluff
BIS M-1
131072 bytes 114688 bytes FRAM
BIS M-1_ _-20
Fujitsu
MB89R112
8192 bytes
7680 bytes
FRAM
* Can only be used in conjunction with BIS M-4_ _-0_ _-401-…read/write device
Advantages of IO-Link:
– Uniform, simple wiring of different devices
– The host system can be used to change the device parameters
– Remote querying of diagnostic information is possible
– Centralized data retention of the device parameters is possible
The manufacturer-specific standard IO-Link sends not only the actual process signal, but also all
relevant parameter and diagnostic data on the process level over a single standard cable.
Communication is based on a standard UART protocol with 24V pulse modulation; no separate
power supply is required.
The BIS M IO-Link uses three-conductor technology (physics 2) and operates with a transfer rate
of 38400 (COM2). The data quantity of the process data is 10 bytes
(BIS M-4 _ _ -045-00 _ -07-S4) or 32 bytes (BIS M-4 _ _ -072-00 _ -07-S4) in each direction
(see
chapter 9 "Process data" on page 48)
.
4.7 Supported Data
Carrier Types
4.8 IO-Link Basic
Knowledge
4
Basic Knowledge
BIS M-4 _ _ IO-Link Device
Read/Write Device
Summary of Contents for BIS M-4 045 0 07-S4 Series
Page 2: ...www balluff com...
Page 4: ...www balluff com www balluff com...
Page 67: ...www balluff com 65 BIS M 4_ _ IO Link Device Schreib Leseger t...
Page 70: ...www balluff com www balluff com...
Page 133: ...www balluff com 65 BIS M 4_ _ IO Link Device Read Write Device...
Page 135: ...BIS M 4_ _ 045 _0_ 07 S4 BIS M 4_ _ 072 _0_ 07 S4...
Page 136: ...www balluff com www balluff com...
Page 141: ...www balluff com 7 1 BIS CRC DPP EMC LSB MSB PC SIO IO SPDU PLC TCP 1 6 1 7 BIS M 4_ _ IO Link...
Page 142: ...8 BIS M 4xx_ _ BIS M EMC A IO Link BIS M 4_ _ 24 A 2 1 2 2 2 3 2 BIS M 4_ _ IO Link...
Page 152: ...18 3 IO Link M12 A 1 24 V 2 3 GND 4 C Q 2 2 2 IO Link IO Link RC 3 2 BIS M 4_ _ IO Link...
Page 199: ...www balluff com 65 BIS M 4_ _ IO Link...
Page 201: ......