58
Error
code
Meaning
Remedy
01
hex
No data carrier in read/write range
Data carriers must already be in the
read/write range when a command is
sent; otherwise dynamic mode must be
configured.
02
hex
Read error
Repeat job.
03
hex
Data carrier was removed from the read
range of the head during reading.
04
hex
Write error
Repeat job.
05
hex
Data carrier was removed from the write
range of the read/write head during
writing.
07
hex
AV is set, but the command designator is
invalid or missing. Or: number of bytes is
00
hex
.
Please check and correct.
0E
hex
CRC error
Data carrier was not successfully read.
Possible causes:
– Data carrier defective
– Transmission failed
– Data carrier not CRC capable
0F
hex
Bit string error
The two headers in the output buffer and
in the host system do not agree.
The bit strings must be matched (
see
"Output buffer," page 48
20
hex
Addressing of the job lies outside of the
memory range of the data carrier.
Please correct addressing, taking into
account the used data carrier.
21
hex
Calls up a function that is not possible
with the current data carrier.
Observe permissible commands for the
current data carrier.
Note
If an error occurs, a new command cannot be executed until the AV has first been
deleted, i.e. the faulty job has been completed in full.
9.5 Error Codes
9
Device Function
BIS M-4 _ _ IO-Link Device
Read/Write Device
Summary of Contents for BIS M-4 045 0 07-S4 Series
Page 2: ...www balluff com...
Page 4: ...www balluff com www balluff com...
Page 67: ...www balluff com 65 BIS M 4_ _ IO Link Device Schreib Leseger t...
Page 70: ...www balluff com www balluff com...
Page 133: ...www balluff com 65 BIS M 4_ _ IO Link Device Read Write Device...
Page 135: ...BIS M 4_ _ 045 _0_ 07 S4 BIS M 4_ _ 072 _0_ 07 S4...
Page 136: ...www balluff com www balluff com...
Page 141: ...www balluff com 7 1 BIS CRC DPP EMC LSB MSB PC SIO IO SPDU PLC TCP 1 6 1 7 BIS M 4_ _ IO Link...
Page 142: ...8 BIS M 4xx_ _ BIS M EMC A IO Link BIS M 4_ _ 24 A 2 1 2 2 2 3 2 BIS M 4_ _ IO Link...
Page 152: ...18 3 IO Link M12 A 1 24 V 2 3 GND 4 C Q 2 2 2 IO Link IO Link RC 3 2 BIS M 4_ _ IO Link...
Page 199: ...www balluff com 65 BIS M 4_ _ IO Link...
Page 201: ......