www.balluff.com
53
The following examples show the protocol sequence in various situations.
Start the device, still no data in the output buffer:
Command from controller
BIS M-4_ _-045-... reaction
1.
Process output buffer:
2.
Process input buffer:
00
hex
GR, KA, AV = 0
00
hex
Set BB
09
hex
GR, KA, AV = 0
01
hex
e.g. 10
hex
= V 1.00
02
hex
e.g. 10
hex
09
hex
Set BB
Reaction to Tag Present = no and new data carrier in the read range:
Command from controller
BIS M-4_ _-045-... reaction
1.
Process output buffer:
2.
Process input buffer:
00
hex
GR, KA, AV = 0
00
hex
Set CP
09
hex
GR, KA, AV = 0
09
hex
Set CP
Reaction to Tag Present = serial number and new data carrier in the read range:
Command from controller
BIS M-4_ _-045-... reaction
1.
Process output buffer:
2.
Process input buffer:
00
hex
GR, KA, AV = 0
00
hex
Set CP
09
hex
GR, KA, AV = 0
01 ... 08
hex
UID
09
hex
Set CP
Reaction to Tag Present = read (start address 5) and data carrier in the read range:
Command from controller
BIS M-4_ _-045-... reaction
1.
Process output buffer:
2.
Process input buffer:
00
hex
GR, KA, AV = 0
00
hex
Set CP
09
hex
GR, KA, AV = 0
01
hex
Address 5 read data
...
Address 12 read data
01 ... 08
hex
UID
09
hex
Set CP
9.4 Protocol
examples
Example 1.
(for 10 bytes of
process data)
Example 2.
(for 10 byte of
process data)
Example 3.
(for 10 bytes of
process data)
Example 4.
(for 10 bytes of
process data)
9
Device Function
BIS M-4 _ _ IO-Link Device
Read/Write Device
Summary of Contents for BIS M-4 045 0 07-S4 Series
Page 2: ...www balluff com...
Page 4: ...www balluff com www balluff com...
Page 67: ...www balluff com 65 BIS M 4_ _ IO Link Device Schreib Leseger t...
Page 70: ...www balluff com www balluff com...
Page 133: ...www balluff com 65 BIS M 4_ _ IO Link Device Read Write Device...
Page 135: ...BIS M 4_ _ 045 _0_ 07 S4 BIS M 4_ _ 072 _0_ 07 S4...
Page 136: ...www balluff com www balluff com...
Page 141: ...www balluff com 7 1 BIS CRC DPP EMC LSB MSB PC SIO IO SPDU PLC TCP 1 6 1 7 BIS M 4_ _ IO Link...
Page 142: ...8 BIS M 4xx_ _ BIS M EMC A IO Link BIS M 4_ _ 24 A 2 1 2 2 2 3 2 BIS M 4_ _ IO Link...
Page 152: ...18 3 IO Link M12 A 1 24 V 2 3 GND 4 C Q 2 2 2 IO Link IO Link RC 3 2 BIS M 4_ _ IO Link...
Page 199: ...www balluff com 65 BIS M 4_ _ IO Link...
Page 201: ......