www.balluff.com
45
The "Action on tag present" parameter specifies how the read/write device is to react if a new
data carrier is detected in the field. The default setting is to send the UID (serial number). In
addition, it is possible to set that nothing or a selected range of 8 bytes is to be sent immedia-
tely as read data. The following values are permissible:
Index 40
hex
, subindex 3
hex
- 1 byte
00
hex
No action
01
hex
Send UID immediately (default setting)
07
hex
Immediately send 8 bytes of data beginning at a set address (parameter "Autoread
start address")
This parameter is only valid if "Autoread" was selected as the action on tag present. The start
address can be set via subindices 4
hex
(low byte) and 5
hex
(high byte). The value range is depen-
dent on the specification of the data carrier; take this into account. An incorrect setting prevents
autoread from functioning; no data is output.
This parameter offers the possibility of specifying certain data carrier models that are to be
detected. All models, all BIS M1_ _-01 models or all BIS M1_ _-02 models can be selected. The
data carriers are detected more quickly if only those that are used are configured. The following
values are permissible:
Index 40
hex
, subindex 6
hex
- 1 byte
00
hex
All data carrier models supported by Balluff (default setting)
FE
hex
All data carriers of type Mifare*
FF
hex
All data carriers of type ISO 15693*
* Data carrier types
The set parameters are stored in the EEPROM memory of the BIS M IO-Link device. On restart,
the most recently used parameters are used.
If the IO-Link parameter server is activated on the IO-Link master, configuration occurs automati-
cally when the device is exchanged.
Note
Should it be necessary to exchange a BIS M IO-Link device in the system, make
certain that the correct parameter settings are programmed in the new device.
Action if tag
present
Start address for
autoread
Data carrier type
7.3 Saving the
Parameter Data
7
Configuring the Read/Write Device
BIS M-4 _ _ IO-Link Device
Read/Write Device
Summary of Contents for BIS M-4 045 0 07-S4 Series
Page 2: ...www balluff com...
Page 4: ...www balluff com www balluff com...
Page 67: ...www balluff com 65 BIS M 4_ _ IO Link Device Schreib Leseger t...
Page 70: ...www balluff com www balluff com...
Page 133: ...www balluff com 65 BIS M 4_ _ IO Link Device Read Write Device...
Page 135: ...BIS M 4_ _ 045 _0_ 07 S4 BIS M 4_ _ 072 _0_ 07 S4...
Page 136: ...www balluff com www balluff com...
Page 141: ...www balluff com 7 1 BIS CRC DPP EMC LSB MSB PC SIO IO SPDU PLC TCP 1 6 1 7 BIS M 4_ _ IO Link...
Page 142: ...8 BIS M 4xx_ _ BIS M EMC A IO Link BIS M 4_ _ 24 A 2 1 2 2 2 3 2 BIS M 4_ _ IO Link...
Page 152: ...18 3 IO Link M12 A 1 24 V 2 3 GND 4 C Q 2 2 2 IO Link IO Link RC 3 2 BIS M 4_ _ IO Link...
Page 199: ...www balluff com 65 BIS M 4_ _ IO Link...
Page 201: ......