6
IO-Link interface (continued)
Index assignment of switching channels
Channel number
Assigned channel Comment
0 (0x00)
BDC1
Binary data channel 0 (
default
)
1 (0x01)
BDC1
Binary data channel 1 (Bit 0 in PD)
2 (0x02)
BDC2
Binary data channel 2 (Bit 1 in PD)
3 (0x03)
BDC3
Binary data channel 3 (Bit 2 in PD)
255 (0xFF)
BDC1…3
Return all switching channel settings to factory default.
Tab. 6-11: Index assignment of switching channels
Returning all switching channel settings to factory
default
Index
Subindex
Access
Value
Hex.
Dec.
Hex. Dec.
1.
Select switching channel.
003A
58
00
0
Write only
Channel number
1)
2.
Return all settings of the previously selected switching
channel to factory settings
2)
.
0002
2
00
0
Write only
0x4E
1)
See Tab. 6-11 on page 16, hexadecimal value
2)
See chapter Factory settings on page 17
6.12 Teach-in of the measuring range
The start and end points of the curve (Slmin and Slmax)
can be defined by teaching in to indicate the gradient
progress and gradient value of the curve.
Teach-in process of the measuring range
Index
Subindex
Access
Value
Hex.
Dec. Hex. Dec.
1.
Activate the measuring range settings
(address 0xC0/192
10
).
003A
58
00
0
Write only
0xC0
2.
Move target to new Slmin.
3)
3.
Temporarily save the current distance as Slmin.
0002
2
00
0
Write only
0x4B
4.
Move target to new Slmax.
4)
5.
Temporarily save the current distance as Slmax.
0002
2
00
0
Write only
0x4C
6.
Apply and activate values for the new measuring range Slmin/
Slmax.
0002
2
00
0
Write only
0x4D
3)
Within the original linear range
4)
Within the original linear range and at least 5.7 mm
The teach-in process has no time limit.
The minimum distance between start and end point must
be set to a value greater than 1/3 Slmax.
The Slmin start point value must always be smaller than
Slmax.
The start point Slmin is initially saved temporarily and can
then be overwritten any number of times.
If the target leaves the measuring range during
teach-in, the error message
TEACH_STATE_ERROR is shown.
If the measuring range is changed by teach-in, any
previously saved switching positions (BDCs) are deleted.
The new curve offset and gradient value set by teach-in
can be read out as described in Tab. 6-7 on page 12.
16
english
BIP LD2-T017-04-BP _ _ / BP _ _ -S4
Inductive Positioning System
Summary of Contents for BIP LD2-T017-04-BP S4 Series
Page 2: ...www balluff com...
Page 3: ...BIP LD2 T017 04 BP_ _ BIP LD2 T017 04 BP_ _ S4 Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 22: ......
Page 23: ...BIP LD2 T017 04 BP_ _ BIP LD2 T017 04 BP_ _ S4 User s Guide english...
Page 24: ...www balluff com...
Page 42: ......
Page 43: ...BIP LD2 T017 04 BP_ _ BIP LD2 T017 04 BP_ _ S4 Notice d utilisation fran ais...
Page 44: ...www balluff com...
Page 62: ......
Page 63: ...BIP LD2 T017 04 BP_ _ BIP LD2 T017 04 BP_ _ S4 Manuale d uso italiano...
Page 64: ...www balluff com...
Page 82: ......
Page 83: ...BIP LD2 T017 04 BP_ _ BIP LD2 T017 04 BP_ _ S4 Manual de instrucciones espa ol...
Page 84: ...www balluff com...
Page 102: ......
Page 103: ...BIP LD2 T017 04 BP_ _ BIP LD2 T017 04 BP_ _ S4...
Page 104: ...www balluff com...
Page 110: ...5 1 BIP 1 2 3 BIP BIP 5 2 BIP BIP 5 8 BIP LD2 T017 04 BP_ _ BP_ _ S4...
Page 122: ......
Page 123: ...BIP LD2 T017 04 BP_ _ BIP LD2 T017 04 BP_ _ S4...
Page 124: ...www balluff com...
Page 130: ...5 1 BIP 1 2 3 BIP BIP 5 2 BIP BIP 5 8 BIP LD2 T017 04 BP_ _ BP_ _ S4...