Programming or Changing Parameters
when Security Code Not Used
Use the following procedure to program or change a parameter already programmed into the control
when a security code is not being used. Example below changes operating mode from keypad to
bipolar.
3-20 KEYPAD PROGRAMMING AND OPERATION
Action
Description
Display
Comments
Apply Power
Display illuminates
Logo display for
for 5 seconds
Press
P R O G
Key
Enter program mode
First programming
Press or Key
Scroll to
INPUT
block
display
[
ENTER
] accesses
Press
ENTER
Key
INPUT
block
parameters
Press
P R O G
Key
Allows operating mode
Keypad mode is
selection
factory preset
Press Key
Scroll through
available range to
Typical selection
make selection
Press
ENTER
or
Saves selected parameter
P R O G
Key
to memory
Press Key
Scroll to
EXIT
block
Press
ENTER
Key
Return to start
of Input block
Press
DISP
Key
Return to display
Typical display
mode
B A L D O R
MOTORS & DRIVES
STPMOTOR SPEED
LOCAL
0 RPM
STPMOTOR SPEED
R E M O T E
0 RPM
PRESS ENTER
FOR
OPERATINGM O D E
P:
K E Y P A D
OPERATINGM O D E
P:
BIPOLAR
PRESS ENTER
FOR
PRESS ENTERFOR
INPUT
PRESS ENTER
FOR
OPERATING M O D E
P: BIPOLAR
STP 0V
0
R P M
MN723H-10/95 11/28/95 1:12 AM Page 74 (Black plate)
Summary of Contents for 23H Series
Page 11: ...1 8 GENERAL INFORMATION MN723H 10 95 11 28 95 1 07 AM Page 12 Black plate...
Page 83: ...3 30 KEYPAD PROGRAMMING AND OPERATION MN723H 10 95 11 28 95 1 13 AM Page 84 Black plate...
Page 99: ...4 16 DIAGNOSTIC INFO AND TROUBLESHOOTING MN723H 10 95 11 28 95 1 14 AM Page 100 Black plate...
Page 125: ...5 26 APPENDIX G MN723H 10 95 11 28 95 1 21 AM Page 126 Black plate...
Page 126: ...MN723H 10 95 11 28 95 1 21 AM Page 127 Black plate...