Table 2.2A Series 23H Stock Single Phase Rating Wire Size and Protection Devices
230 VAC Controls
Catalog No.
Max CT
Input
Input Fuse
Input Fuse
Wire Gauge
HP
Breaker
Fast Acting
Time Delay
AWG
SD23H2A03-E
1
15A
15A
15A
14
SD23H2A04-E
2
15A
15A
15A
14
SD23H2A07-E
3
15A
15A
15A
14
SD23H2A10-E
5
15A
15A
15A
14
SD23H2A15-E
7.5
20A
20A
20A
12
SD23H2A22-E
10
30A
30A
30A
10
SD23H2A30-ER
15
40A
40A
40A
8
SD23H2A45-ER
20
60A
60A
60A
4
SD23H2A55-ER
25
75A
75A
75A
4
NOTE:
ALL WIRE SIZES BASED ON 75° C COPPER WIRE, 40°C AMBIENT, 3% LINE
IMPEDANCE. HIGHER TEMPERATURE SMALLER GAUGE WIRE MAY BE USED
PER NEC AND LOCAL CODES.
2-8
INSTALLATION
MN723H-10/95 11/28/95 1:08 AM Page 20 (Black plate)
Summary of Contents for 23H Series
Page 11: ...1 8 GENERAL INFORMATION MN723H 10 95 11 28 95 1 07 AM Page 12 Black plate...
Page 83: ...3 30 KEYPAD PROGRAMMING AND OPERATION MN723H 10 95 11 28 95 1 13 AM Page 84 Black plate...
Page 99: ...4 16 DIAGNOSTIC INFO AND TROUBLESHOOTING MN723H 10 95 11 28 95 1 14 AM Page 100 Black plate...
Page 125: ...5 26 APPENDIX G MN723H 10 95 11 28 95 1 21 AM Page 126 Black plate...
Page 126: ...MN723H 10 95 11 28 95 1 21 AM Page 127 Black plate...