Level 2 Programming Blocks
5-21
APPENDIX G
BLOCK TITLE
DESCRIPTION AND SERIAL
RANGE
FACTORY
PAGE
USER
MODE PARAMETER NUMBER
PRESET
SETTING
BRUSHLESS
RESOLVER ALIGN
P1601
22.3 REF
CALC
3-10
CONTROL
SPEED FILTER
P1602
0-7
CALC
3-10
FEEDBACK ALIGN
P1603
FORWARD, REVERSE
FORWARD
3-10
CURRENT PROP GAIN
P1604
0-255
20
3-10
CURRENT INT GAIN
P1605
O-100
50
3-10
SPEED PROP GAIN
P1606
0-255
10
3-10
SPEED INT GAIN
P1607
0-9.99 Hz
1.00 Hz
3-10
SPEED DIFF GAIN
P1608
0-100
0
3-10
POSITION GAIN
P1609
0-9999
CALC
3-10
PRESS ENTER FOR MENU EXIT
LEVEL 2
ENTERS LEVEL 2 BLOCKS
BLOCKS
PRESS ENTER
EXITS PROGRAM MODE AND RETURNS TO DISPLAY MODE
FOR PROGRAM
EXIT
BLOCK TITLE
DESCRIPTION AND SERIAL
RANGE
FACTORY
PAGE
USER
MODE PARAMETER NUMBER
PRESET
SETTING
OUTPUT LIMITS
OPERATING ZONE
P2001
STD CONST TQ.
QUIET
STD VAR TQ.
CONST.
3-11
QUIET CONST TQ.
TQ.
MIN OUTPUT SPEED
P2002
0-MAX SPEED
0 RPM
MAX OUTPUT SPEED
P2003
0-32767
RATED
MOTOR
3-11
SPD
PK CURRENT LIMIT
P2004
0-PEAK RATED
PK
CURRENT
CONTROL
3-11
RATING
PWM FREQUENCY
P2005
1.0-5 KHz (STANDARD
8.0 KHz
STD = 2.5 KHz
1.0-16 KHz (QUIET)
3-11
QUIET = 8.0KHz
TORQ RATE LIMIT
P2006
0-10.00 S
0.00 S
3-12
PRESS ENTER FOR MENU EXIT
MN723H-10/95 11/28/95 1:21 AM Page 121 (Black plate)
Summary of Contents for 23H Series
Page 11: ...1 8 GENERAL INFORMATION MN723H 10 95 11 28 95 1 07 AM Page 12 Black plate...
Page 83: ...3 30 KEYPAD PROGRAMMING AND OPERATION MN723H 10 95 11 28 95 1 13 AM Page 84 Black plate...
Page 99: ...4 16 DIAGNOSTIC INFO AND TROUBLESHOOTING MN723H 10 95 11 28 95 1 14 AM Page 100 Black plate...
Page 125: ...5 26 APPENDIX G MN723H 10 95 11 28 95 1 21 AM Page 126 Black plate...
Page 126: ...MN723H 10 95 11 28 95 1 21 AM Page 127 Black plate...