![Axis 5600+ User Manual Download Page 90](http://html1.mh-extra.com/html/axis/5600/5600_user-manual_3038809090.webp)
UNIX
Section 8: Setting Up - UNIX
AXIS 5600+ User’s Manual
90
2. Select the
Printer4
tab.
3. Enter the string
1B 26 6C 34 48
in the
String Before Print Job
text field.
4. Enter the string
1B 26 6C 31 48
in the
String After Print Job
text field.
5. Click the
OK
button.
String Substitutions
The string substitution function performs search and replace
operations on the print data. The primary application is to replace
printer control commands. Up to twenty string substitutions may be
specified individually for each logical printer.
All strings must be entered as hexadecimal byte values, and each match
and substitute string must be preceded by a count byte.
You substitute command strings by editing the String Substitutions
(PRx_STR) parameter.
Example:
Assume that you want to replace the UNIX New Line (hex
0A
) with
an ASCII NewLine (hex
0D 0A
) for logical printer PR1.
Follow the instructions below to substitute command strings:
1. From the print server’s internal web page, select
Admin | Logical
Printer Settings.
2. Select the
PR1
Web page.
3. Enter the string
01 0A 02 0D 0A
in the
String Substitutions
text
field.
Hex Code
Explanation
01
length of the string you want to re-
place
0A
the string you want to replace
02
length of the substitute string
0D 0A
the substitute string