User’s Manual
Section 12: Test Button
145
Factory Default
Settings
Follow the instructions below to reset the AXIS 5600+ to the factory
default settings:
1. Remove the external power supply to switch off the AXIS 5600+.
2. Press and hold down the test button, while you plug the external
power supply back in. Continue to hold down the test button,
until the network indicator begins to flash at one second intervals.
This should take approximately 5 seconds.
3. Release the test button and wait until the network indicator
flashes at least five times.
4. Press and hold the test button again until the network indicator
remains constantly lit.
5. Restart the AXIS 5600+ by disconnecting and reconnecting the
external power supply.
The AXIS 5600+ is now reset to factory default settings.
Note:
❏
All parameters except Node Address (NODE_ADDR), Internet
Address (IP_ADDR) and DHCP enabled or disabled
(DHCP_ENABLE.) are reset. If you want to change the these
parameters, use either AXIS NetPilot or any standard Web
browser. Please refer to
Section 9 Management & Configuration
,
on page 96.