328
DSView 3 Software Installer/User Guide
10. If you want the managed appliances you are migrating to be accessible only by this DSView 3
server, enable the
Enable secure mode
checkbox. If you want the managed appliances you are
migrating to be accessible by any DSView 3 software system, disable the
Enable secure mode
checkbox. Click
Next
.
NOTE:
If you are migrating units from the AlterPath Manager, enabling secure mode is recommended.
11. Click
Finish
. The Tasks window will open. You may display the current progress of the
migration task by clicking on the name of the task.
12. Repeat the preceding steps for each type of managed appliance that you wish to migrate.
Units successfully migrated into the DSView 3 software system will appear in Units View
windows and the Migration Status field for these units will indicate Migration Completed.
Task: Sending an IPMI chassis control command to target devices
This command powers up, powers down, cycles the power (power down and then power up),
performs a gentle shutdown or resets one or more IPMI target devices.
You must have Control Target Device Power rights to send an IPMI chassis control command. See
About Access Rights
on page 144.
Once this task is added, you may run it on demand at any time; see
Running tasks manually
on
page 334.
To add the task:
1.
Click the
System
tab.
2.
Click
Tasks
in the top navigation bar. The Tasks window will open.
3.
Click
Add
. The Add Task Wizard will appear.
4.
Select
Send IPMI chassis control command to target devices
from the drop-down menu. Type a
1-64 character name for the task.
5.
Select a time to run the task (see
Specifying when to run tasks
on page 320). Click
Next
.
6.
The Select Unit Group window will open. Select
All Target Devices
or select a particular unit
group to configure from the menu. See
Grouping Units
on page 205. Then click
Next
.
7.
The Select Target Devices window will open. Select one or more IPMI target devices to
chassis control from the Available Target Devices list, then click
Add
. The IPMI target devices
will be moved to the Target Devices to Control list. Click
Next
.
8.
The Select IPMI Control Function window will open. Select the power control function you
wish to perform on the IPMI target devices, then click
Next
.
Turn Power On
- powers up the specified devices.
Turn Power Off
- powers down the specified devices.
Cycle Power
- powers down and then power up the specified devices. *
Reset
- performs a hard reset of the specified devices.
Graceful Shutdown
- performs a graceful shutdown of the specified devices. *
Summary of Contents for Network Device SPC420
Page 1: ...DSVIEW 3 Installer User Guide ...
Page 2: ......
Page 4: ......
Page 14: ...xii DSView 3 Software Installer User Guide ...
Page 16: ...xiv DSView 3 Software Installer User Guide ...
Page 20: ...xviii DSView 3 Software Installer User Guide ...
Page 42: ...22 DSView 3 Software Installer User Guide ...
Page 52: ...32 DSView 3 Software Installer User Guide ...
Page 78: ...58 DSView 3 Software Installer User Guide ...
Page 98: ...78 DSView 3 Software Installer User Guide ...
Page 122: ...102 DSView 3 Software Installer User Guide ...
Page 144: ...124 DSView 3 Software Installer User Guide ...
Page 184: ...164 DSView 3 Software Installer User Guide ...
Page 224: ...204 DSView 3 Software Installer User Guide ...
Page 238: ...218 DSView 3 Software Installer User Guide ...
Page 248: ...228 DSView 3 Software Installer User Guide ...
Page 268: ...248 DSView 3 Software Installer User Guide ...
Page 306: ...286 DSView 3 Software Installer User Guide ...
Page 338: ...318 DSView 3 Software Installer User Guide ...
Page 358: ...338 DSView 3 Software Installer User Guide ...
Page 368: ...348 DSView 3 Software Installer User Guide ...
Page 374: ...354 DSView 3 Software Installer User Guide ...
Page 431: ......
Page 432: ...For Technical Support www avocent com support 590 395 501M ...