260-668080-001 Rev 002 March 2013
53
Eclipse Edge User Manual
Circuits
The Edge Circuits screen is used to assign and check cross-connects for Ethernet and/
or NxE1 traffic.
shows a Circuits screen. Its operation is described in the following table.
Figure 4-14.
IDU Circuits Screen
Item
Description
1
Shows the Ethernet circuits configuration.
• Capacity is set in the DAC ES module using the up/down tabs. In this
example 20 Mbps (10xE1) has been selected.
• Ethernet capacity cannot exceed the available link capacity set in the
Link/RAC Plug-ins screen.
• If the requested capacity (requested capacity in the DAC ES Plug-ins
screen) does not match an exact Nx2 Mbps multiple, the Configured
capacity will be the capacity needed to accommodate the request,
which will be higher by nominally 1 Mbps to meet the Nx2 Mbps rule.
For example, if 21 Mbps is requested, the Configured capacity will be
22 Mbps.
• Channel indicates the DAC ES channel used to connect the user ports to
the Link module. For Edge, there is only one channel, C1.
• Channel Port indicates the number of 2 Mbps channel ports configured
to support the Ethernet capacity, and the channel ports used.
• Radio Port indicates the assignment of 2 Mbps ports on the Link/RAC
module. In this example C1 Channel Ports 1 to 10 are mapped to Radio
Ports 7 to 16. This channel to radio port mapping is not user editable.
1
2
3
4
Summary of Contents for ECLIPSE EDGE
Page 1: ...ECLIPSE EDGE Version 5 USER MANUAL 260 668080 001...
Page 2: ......
Page 3: ...Eclipse Edge Microwave Radio System User Manual Software Version 5 0 March 2013...
Page 14: ...16 Aviat Networks INDEX...
Page 18: ......
Page 26: ...8 Aviat Networks Chapter 1 Health and Safety...
Page 272: ...36 Aviat Networks Chapter 3 Eclipse Edge Installation...
Page 273: ......