- 34 -
speed, the remote control can set high fan, middle fan and low fan except automatic fan; The
performance condition of the air door is same as the one under refrigeration mode; This mode
includes the timing function, auto-restart (optional), negative ion (optional), I feel
(
optional
)
⑺
Heating mode
The setting temperature can be decided and adjusted by the remote control within the control
range of 16
℃
- 32
℃
through the button of temp. Add “+” and temp. Reduce “-”. Press the
button “wind speed option” to choose the wind speed among the options of automatic fan,
high fan, middle fan and mute fan. The other conditions refer to the following:
⑴
When TA-3-TS
≤
-1
℃,
if satisfying the 3 minutes protection delay condition for compressor,
the compressor and outdoor fan start, and the indoor fan runs in accordance with the anti-cold
wind condition.
⑵
When TA-3-TS
≥
1
℃,
if satisfying the 3 minutes protection delay condition for compressor
,
the compressor and outdoor fan stop working, and the indoor fan runs in accordance with the
anti-cold wind condition.
⑶
When TA-3=TS
,
remain the previous status
;
⑷
Temperature display has the temperature compensation of 3
℃
⑸
Automatic wind speed control
:
TA
<
TS
,
run at high fan speed
;
TS
≤
TA
<
TS +2
℃,
run at middle fan speed
;
TA
≥
TS + 2
℃,
run at low fan speed
;
There is no 3 minutes protection delay when the wind speed turns to high fan from the low fan;
there is 3 minutes protection delay when the wind speed turns to low fan from the high fan;
⑹
When heating process ongoing, the button of “Swing” can control the swing leaves to swing
or stop
;
⑺
Being electrified initially, the compressor has no 3 minutes protection delay. The
compressor starts 10 seconds later after the start of the four-way valve, and the outdoor fan
starts 2 seconds later after the start of the compressor; Set the TS
<
TA-3 by remote control
,
the compressor stops immediately and without the 3 minutes protection delay;
⑻
This mode includes the timing function, sleeping function, auto-restart (optional), negative
ion (optional), I feel
(
optional
)
.
⑼
Being electrified initially, the four-way valve starts immediately ,and the compressor starts
10 seconds later; During the operation condition of the compressor, the four-way valve stops
after 2min50s protection delay when stops the air-conditioner or switch mode;
In the case of compressor stops, the four-way valve stops immediately once stopping the
air-conditioner
;
⑽
Anti-cooling wind and residual-heat Removing function:
The wind speed of the indoor fan is controlled by TE, and the specific conditions are as below:
Anti-cold wind when compressor runs
:
①
When TE is in rise status, if Te<30
℃
,the indoor fan turns off;30
℃
≤
TE
<
38
℃
,the indoor fan
runs at low fan speed;Te
≥
38
℃
, the indoor fan runs at setting wind speed;
②
When Te in fall status, if TE>34
℃
,the indoor fan runs at the setting fan speed;28
℃<
TE
≤
34
℃
,the indoor fan runs at the low fan speed;TE
≤
28
℃,
the indoor fan turns off.
Summary of Contents for ASW-H09A4/EAR1-dw
Page 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Page 6: ... 4 Remote Controller Instructions ...
Page 7: ... 5 ...
Page 8: ... 6 ...
Page 9: ... 7 ...
Page 10: ... 8 ...
Page 11: ... 9 ...
Page 12: ... 10 ...
Page 13: ... 11 ...
Page 14: ... 12 ...
Page 48: ... 46 ...
Page 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Page 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Page 76: ......