- 38 -
cancel the previous set setting timing and sleeping functions
⑾
Self-detecting function
Press the Emergency button and electrify the air-conditioner, the self-detecting
process starts after the buzzer delivers short tone twice:
Start the electric heating, run the indoor fan at a high fan speed, open the air door to
be the maximum
Æ
the digital display and three indicating light on in 1 second
Æ
digital
displays “11”
、
“22”
、
“33”
、
“44” in turn and 1second for each of them
Æ
Working light on
1 second
Æ
Timing light on 1 second
Æ
Sleeping light on 1 second
Æ
Each phase of the
stepping motor moves in 1 second
Æ
the indoor fan runs for 1 second at low fan speed
and middle fan speed separately
Æ
the compressor moves for 1 second
Æ
The
four-way valve moves for 1 second
Æ
Outdoor fan moves for 1 second
Æ
Negative ion
generator moves for 1 second
Æ
buzzer deliver one short tone
Æ
Electric heating runs
30 Seconds and stops, then the air conditioner turn into the waiting status, the
self-testing is ended.
⑿
Fault indication
When there is faults happen to the air-conditioner, the timing lights on the display panel will
indicate the corresponding fault codes, which are specifically reflected as the following:
For LED display:
FAULT
DISPLAY MODE
DISPLAY PRIORITY
APPEARANCE
TA
abnormity
Timer lamp flash
1
times/8 seconds
2 AC
stopped
TE
abnormity
Timer lamp flash
2
times/8 seconds
3 AC
stopped
TW
abnormity
Timer lamp flash
8
times/8 seconds
4 AC
hasn’t
stopped
For Digital display:
FAULT
DISPLAY MODE
DISPLAY PRIORITY
APPEARANCE
TA abnormity
display“E1”
2
AC stopped
TE abnormity
display “E3”
3
AC stopped
TW
abnormity
display “E2”
4
AC hasn’t
stopped
⒀
The definition of the swing angle
(Picture 3)It shows the swing angles of the types 18000BTU and 24000BTU stepping
motor
,
the air door’s swing angle of 18000BTU,24000BTU and 7000BTU,12000BTU are
same
,
but the swing directions of the motors are not same.
①
Once being electrified, the air door effect a motion of totally closed, and the swinging speed
is 1 step/4ms
;
②
After the air-conditioner turns on, the air door effect a motion of total opening, and swing to
Summary of Contents for ASW-H09A4/EAR1-dw
Page 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Page 6: ... 4 Remote Controller Instructions ...
Page 7: ... 5 ...
Page 8: ... 6 ...
Page 9: ... 7 ...
Page 10: ... 8 ...
Page 11: ... 9 ...
Page 12: ... 10 ...
Page 13: ... 11 ...
Page 14: ... 12 ...
Page 48: ... 46 ...
Page 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Page 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Page 76: ......