- 16 -
7. Expelling the air in the pipes and the indoor unit
Expelling the air: humid air in the refrigerating system might cause
trouble of compressor.
①
Take off the cover from the stop valve and T-branch valve.
②
Take off the auxiliary cover from the T-branch valve.
③
Turn the stop valve rod anti-clock wise to an angle of 90 degree,
keep it open for 8 seconds and close the valve.
④
Check whether there is air leakage at all connection parts of
pipes.
⑤
Push the top rod of T-branch valve by hexagon wrench to expel
air.
⑥
Repeat the third and fifth steps.
⑦
Open the stop and T-branch valve with a hexagon wrench to
make the unit operate.
⑧
No leakage is allowed, please check all the piping connection
parts. You must test the leakage, generally, it can be tested by soap
water.
8. Electrical connection
①
Unscrew the screw, take off the control panel cover
from the unit.
②
Cooling type: connect the wire to the related
connection point on the panel and connect the signal
connection plug.
Remarks: yellow and green cord should be connected to
connection point with
mark.
③
Fasten the fixture of wire to control panel.
④
Screw up the control panel cover to its original place.
9. Test running
①
Make sure that the pipes and wires are connected.
②
Make sure that both the liquid valve and gas
valve on the side are completely open.
The connection of power source
¾
Connect the wire to independent power source
socket.
¾
Preparation of remote control.
¾
Run the air-conditioner in cooling operation
mode for 30 minutes or longer.
Performance evaluation
¾
Test the out and in air temperature.
¾
Make sure that the temperature difference
between the out and in air is greater than 8
o
C.
10. Items of attention
①
Fix the machine firmly, otherwise it will produce noise and vibration.
②
Install the outdoor unit where it will not disturb your neighbor.
Summary of Contents for ASW-H09A4/EAR1-dw
Page 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Page 6: ... 4 Remote Controller Instructions ...
Page 7: ... 5 ...
Page 8: ... 6 ...
Page 9: ... 7 ...
Page 10: ... 8 ...
Page 11: ... 9 ...
Page 12: ... 10 ...
Page 13: ... 11 ...
Page 14: ... 12 ...
Page 48: ... 46 ...
Page 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Page 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Page 76: ......